Fall from collapsing structure or equipment 6 to 10 feet · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Evonik Corporation, 8300 WEST ROUTE 24, MAPLETON, ILLINOIS 61547
on — Fractures, affecting the multiple body parts, n.e.c..
Final narrative
An employee was climbing down from a portable manlift when the cage area he was holding onto collapsed and he fell about 6 feet to the floor, breaking his wrist and pelvis. He was hospitalized.
On December 15, 2023, the injured employee was working from a ladder. A co-worker climbed the backside of the ladder and the ladder failed. The injured employee fell approximately 8 feet to the ground and sustained multiple fractures.
An employee was installing grout using a shovel when the precast hollow-core floor gave way, causing them to fall approximately 8-10 feet. The employee sustained a back fracture.
An employee was assisting with assembly of a two-level scaffold. The scaffold fell, causing the employee to fall 8 feet from the second level to the concrete surface below. The employee sustained fractures to the face, jaw, and both wrists.
An employee was repairing an egg collector when the platform collapsed and he fell 10 feet to the concrete floor. The employee sustained a fractured left leg.
An employee was descending a ladder when it collapsed, causing him to fall approximately 8 feet. The employee was hospitalized with a compound fracture to his left leg and a left wrist fracture.
More severe injuries in this industry (NAICS 325199)
Two employees were lifting a roll of steel poly bar (50 inches and approximately 150 pounds) from ground level to a height of 4 feet at the 66-inch rubber calendar. One employee dropped the roll, resulting in the poly bar contacting the injured employee's right knee. The employee was hospitalized with fractured right patella.
Employees were loading a 295-pound transformer onto a pickup truck using a forklift. The injured employee was acting as the spotter. The transformer hit the tailgate of the pickup truck and the spotter's right hand was struck by the transformer, resulting in amputation of the ring fingertip.
An employee was wearing full PPE while emptying a 55-gallon drum of phosphorus pentoxide and fainted, collapsing and striking their head against the ground. The employee was hospitalized and it is likely that heat caused by wearing full body PPE contributed to fainting.
An employee was troubleshooting a plug in the super-absorbent polymer line. The employee opened an inspection port and their right hand was caught in a rotary valve, resulting in the amputation of four fingers between the knuckle and the first joint.
An employee was conducting a quality control measure by taking a chemical sample for lab analysis. When the employee was opening the sample point, it broke off and crude 2-Ethylhexyl thioglycolate (EHTG) shot out at 265 degrees, and it covered the employee's legs and right arm and splashed the right side of their face. The employee was hospitalized with first- and second-degree burns to their right thigh, lower right knee, inner left thigh, and upper left forearm.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was driving a boom lift (in the lowered position) in an exterior dock area. The lift s left wheels rolled onto base plates that covered a 3-foot-deep sump pit. The base plates failed, and one side of the lift dropped. The employee's left leg was caught under the lift basket, and he suffered a fracture to the lower leg including the ankle.