Struck by swinging or slipping object, other than handheld, n.e.c. · Internal injuries to organs and blood vessels of the trunk
At a glance
Federal OSHA recorded a severe workplace injury
at Greenwood, Inc., 1126 N Kimball St, DANVILLE, ILLINOIS 61832
on — Internal injuries to organs and blood vessels of the trunk, affecting the abdomen, except internal location of diseases or disorders.
Final narrative
An employee was struck by a rotation bar during a change-over on a thermoformer machine, injuring his spleen, colon, and pancreas. He was hospitalized.
HospitalizedAbdomen, except internal location of diseases or disordersExtruding, injecting, forming, molding machinery, n.e.c.
On February 2, 2023, an employee was operating a thermoforming machine. The employee's left hand was caught in the machine's production area, and the employee's left thumb tip was amputated.
An employee was using emery cloth to polish a piece of metal shaft stock. The emery cloth and his right index finger got caught in the shaft and the finger was amputated.
On January 19, 2022, an employee was cleaning melted plastic particles off a pull roller in an extruder when his left hand was caught between two rollers resulting in amputation of four fingers (all but the index finger) on the left hand.
A crew was pulling a 4-inch plastic gas pipe off a reel and straightening it for installation. The injured employee stepped up on the trailer to cut the last band holding the pipe in the coil on the reel. As he turned to step off the trailer, the end of the pipe rotated and sprung out of the cage surrounding the coil, striking the employee on the side of the head and knocking him off of the trailer into the roadway. The employee suffered head trauma that required hospitalization.
An employee and a co-worker were performing a pick inside a clear well. They rigged the skid pan that was full of broken concrete. When lifting, the load began to swing toward a wall. The employee tried to stop the skid pan from swinging and was struck by the pan, resulting in fractures to their left hip and wrist.
The employee had just completed refueling a lattice crane that was breaking up material and was winding the fuel hose back into the fuel truck when he was struck by the catwalk/stairs of the crane. The employee was hospitalized with a laceration to his backside, possible internal bleeding, and a broken hip.
An employee was fusing 10-inch black rubber utility pipes together using a pipe fusion machine and could not get the pipes to set correctly. The employee used a nylon strap attached to an excavator to lift one side of a pipe off a steel plate. As his hand was between two pipes, the pipes came back together, partially amputating two of his fingers.
An employee was lifting four bags of a lime blend weighing approximately 10,000 pounds using a crane. The load swung and pinned the employee against a structural I-beam, resulting in fractures to the hip and pelvis.
More severe injuries in this industry (NAICS 326199)
An employee was operating a drill and tap machine. He was placing a part with his right hand and removing a part coming in on the left side. He saw a part that was crooked and went to straighten it. The machine clamped down on his left index finger, degloving the top part of the finger and resulting in a partial amputation.
An employee was performing maintenance on a roll cutting machine in a warehouse. The employee was removing excess grease from the bearings when the machine's chain caught their right index finger. The fingertip was amputated by the chain and sprocket.
During fiberglass work, an employee mixed a methyl ethyl ketone peroxide (MEKP) catalyst with a cobalt chemical that they thought was a dye. A chemical reaction occurred, resulting in an explosion. The employee sustained second-degree burns on his back and a blister on his right arm.
An employee was walking when she tripped over a box on the ground and fell. The employee was hospitalized with a severe dislocation to the hip and leg that required surgery.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was driving a boom lift (in the lowered position) in an exterior dock area. The lift s left wheels rolled onto base plates that covered a 3-foot-deep sump pit. The base plates failed, and one side of the lift dropped. The employee's left leg was caught under the lift basket, and he suffered a fracture to the lower leg including the ankle.