Pedestrian struck by vehicle backing up in nonroadway area · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Probst Electric, W. Belmont and Hwy 71, CRAWFORD, NEBRASKA 69339
on — Fractures, affecting the lower leg(s).
Final narrative
An employee was struck by a forklift that was backing into position. The employee suffered a fractured lower right leg.
HospitalizedLower leg(s)Forklift, order picker, platform truck-powered
On October 1, 2024, an employee was using a handheld electric crimping tool to connect two ends of a ground wire inside a switch cabinet. The employee's finger became caught in the crimping tool when it closed. The employee was hospitalized and sustained a complete transphalangeal amputation of their right middle finger.
An employee was connecting an auger to a drill. The employee's right ring finger was caught in the pinch point between the auger and the hook on the service winch for the drill, causing a laceration to the finger and a partial amputation to the fingertip.
An employee was looking into the bucket of a front-end loader to see how much material was in it. A skid steer backed into the employee, who then fell into the edge of the front loader's bucket and suffered internal bleeding in the abdominal area.
An employee was spotting for a forklift operation. The forklift backed over the employee, who suffered a complete amputation to one lower leg and a partial amputation to the other leg. The employee was hospitalized.
An employee was cleaning his work area and preparing it to begin making air-set molds
when a nearby forklift that was backing out from a load swung around and struck the employee. They sustained a lower left leg fracture.
An employee was performing troubleshooting and maintenance on one of the generators that feed the RF line for glue-laminated timber (glulam) beam production. He was reattaching the outer panel of the generator. A circuit was completed and the employee was electrocuted by the generator and sustained burns. The employee was hospitalized.
An employee was utilizing a utility task vehicle (UTV) to patrol a 138 kV transmission line in a right-of-way. The UTV drove into a washout hole that was approximately 6 feet deep and obstructed by vegetation. The employee sustained a dislocated shoulder, a fractured left humerus, back pain, and a strained ankle. He was hospitalized.
A crew of employees were working to replace a utility pole that was broken by a motor vehicle accident. As the crew was removing equipment from the broken pole, part of the pole broke, fell on the injured employee, and rolled over him. The employee sustained two broken shoulders, multiple broken ribs, and a damaged lung that required hospitalization and surgery.
An Ameren lineman was making secondary voltage connections in a pad-mounted residential feed transformer. The lineman contacted an energized lead bushing, sustained an electrical shock, and was hospitalized.
An employee was stacking concrete blocks for a concrete bunker. As a block was swinging into place, the employee's left leg was pinched between two blocks, resulting in injuries to his left heel and lower leg.
An employee was climbing a ladder to inspect a vent in a restaurant dining area. The ladder slid out on the floor and the employee fell approximately 12 feet onto the ladder and the floor. He was hospitalized with a dislocated shoulder and a back injury.
An employee was filtering a fryer with a fryer filter machine. After going around the corner and then returning to the fryers, the employee stepped into the filter machine. The hot oil burned the employee's right ankle, and the employee was hospitalized.
An employee was cleaning out corn from a grain bin. The sweep auger in the bin was activated and caught his trouser leg. His leg was pulled into the auger, which injured his calf and caused leg fractures and lacerations.