Other fall to lower level, unspecified · Dislocation of joints
At a glance
Federal OSHA recorded a severe workplace injury
at Probst Electric, montrose, MONTROSE, COLORADO 81401
on — Dislocation of joints, affecting the ankle(s).
Final narrative
A transmission pole was in a 42-inch diameter hole that was being backfilled. An employee slipped into the hole and suffered an ankle dislocation.
On October 1, 2024, an employee was using a handheld electric crimping tool to connect two ends of a ground wire inside a switch cabinet. The employee's finger became caught in the crimping tool when it closed. The employee was hospitalized and sustained a complete transphalangeal amputation of their right middle finger.
An employee was connecting an auger to a drill. The employee's right ring finger was caught in the pinch point between the auger and the hook on the service winch for the drill, causing a laceration to the finger and a partial amputation to the fingertip.
An employee was on an A-frame ladder retrieving materials from a shelf. He slipped and fell and his leg got caught in the ladder rungs, breaking his left tibia.
An employee was unloading materials from a flatbed trailer when they fell from the trailer and landed on the ground. The employee sustained a fractured left leg.
An employee was unloading appliances at a customer location for delivery. The employee was moving a water heater to be placed on the liftgate when he stepped backward and fell to the ground. The employee sustained rib and back injuries.
An employee was performing troubleshooting and maintenance on one of the generators that feed the RF line for glue-laminated timber (glulam) beam production. He was reattaching the outer panel of the generator. A circuit was completed and the employee was electrocuted by the generator and sustained burns. The employee was hospitalized.
An employee was utilizing a utility task vehicle (UTV) to patrol a 138 kV transmission line in a right-of-way. The UTV drove into a washout hole that was approximately 6 feet deep and obstructed by vegetation. The employee sustained a dislocated shoulder, a fractured left humerus, back pain, and a strained ankle. He was hospitalized.
A crew of employees were working to replace a utility pole that was broken by a motor vehicle accident. As the crew was removing equipment from the broken pole, part of the pole broke, fell on the injured employee, and rolled over him. The employee sustained two broken shoulders, multiple broken ribs, and a damaged lung that required hospitalization and surgery.
An Ameren lineman was making secondary voltage connections in a pad-mounted residential feed transformer. The lineman contacted an energized lead bushing, sustained an electrical shock, and was hospitalized.
An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.
A concrete batch plant operator was assisting with clearing spoil piles using a skid steer. The skid steer backed into a stationary screen plant. The employee's left little finger was crushed between the controls of the skid steer and the screen plant, resulting in a fracture and laceration. The employee's finger was surgically amputated.
An employee was standing on an extension ladder, using a torquing tool to remove bolts that secured blades to a rotor. When the torquing tool activated, its reaction arm came around and pinched the employee's right middle finger against a lifting eye. His fingertip was amputated.