105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Vanguard Environmental, Inc.

Injured by slipping or swinging object held by injured worker · Amputations

Federal OSHA recorded a severe workplace injury at Vanguard Environmental, Inc., 4800 W. Quincy St., Ste. 101, BROKEN ARROW, OKLAHOMA 74012 on — Amputations, affecting the finger(s), fingernail(s), unspecified.

An employee was cutting paper with a manual cutter. The cutter cut off the top of his left thumb to the bone, requiring surgery for a skin graft.

Hospitalized Amputation Finger(s), fingernail(s), unspecified Cutting handtools-nonpowered, n.e.c.

Mako Contracting, LLC

An employee was using a saw to cut a piece of concrete when the piece gave way and pushed the saw into the employee's leg. The employee's leg was lacerated, requiring stitches and hospitalization.

East Penn Manufacturing

An employee was using a utility knife to cut honeycomb paper when the knife amputated their left index fingertip.

Ash Brothers Fireplace and Chimney Co

An employee was cleaning a resident's chimney. While using a drill, the employee's glove became caught in the drill and their finger was fractured.

RPM & Associates Inc

An employee was grinding some hardfacing on a bulldozer blade when the 9-inch grinder kicked back and lacerated his left leg above the knee. The employee was hospitalized and required surgery.

Tenaris Hickman

An employee was operating a rotating tool to place thread protectors on the end of pipe. Her left hand was on the rotating part of the tool when the tool engaged, resulting in a left forearm fracture and a thumb laceration.

CSD Environmental Services

An employee was operating a hammer drill when his glove got tangled in the drill and his little finger was amputated.

Triumvirate Environmental, Inc.

The employee was working in the back of a micro truck and maneuvering around the materials in the back of the truck. The employee's foot caught on the edge of the truck, causing him to lose balance and fall from the back of the truck to the ground approximately 3.5 to 4 feet below. The employee landed on his feet on the loading dock but rolled his ankle. The employee was hospitalized with a compound fracture of the ankle.

Matrix Environmental Technologies Inc.

An employee was assisting the operator of a soil sampling rig to collect soil samples. He went to remove soil sampling tooling and the energized equipment cycled. His right index fingertip was amputated including the fingernail.

Ironclad Environmental Solutions, Inc.

A truck driver was loading a second roll-off container onto a two-box trailer. He was operating the hydraulic control levers with his left hand, and was holding the D-ring in place on the exterior of the trailer while letting slack out of the winch cable. The employee's right little finger became pinched between the winch cable and the structure of the trailer. The employee required surgical amputation of the distal phalanx.

Montrose Environmental Group, Inc.

An employee was sampling a fluid catalytic cracking (FCC) unit by opening a valve and placing a proving tube inside to collect the sample. The sample taken is a hot gas mixture. When the sample was collected, the flange came undone and fell due to the pressure. The employee sustained an amputation to their right middle fingertip.

Rae Corporation

An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.

Meeco Sullivan

An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.

Edward Jones Investments

An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.

Burgess Manufacturing of Oklahoma Inc.

An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.