Other fall to lower level, unspecified · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at L & P Materials Manufacturing, Inc., 1000 L & P Parkway, MONROE, GEORGIA 30655
on — Fractures, affecting the hip(s).
Final narrative
An employee was releasing the tie-down strap and fell from his truck. He sustained a broken hip, bruised ribs and a right shoulder injury.
HospitalizedHip(s)Truck-motorized freight hauling and utility, unspecified
An employee was on an A-frame ladder retrieving materials from a shelf. He slipped and fell and his leg got caught in the ladder rungs, breaking his left tibia.
An employee was unloading materials from a flatbed trailer when they fell from the trailer and landed on the ground. The employee sustained a fractured left leg.
An employee was unloading appliances at a customer location for delivery. The employee was moving a water heater to be placed on the liftgate when he stepped backward and fell to the ground. The employee sustained rib and back injuries.
An employee was climbing a ladder to get on top of the breakroom. The ladder slipped, causing him to fall to the ground. The employee sustained fractures to his upper back, left foot, and ankle.
An employee was working at a quench conveyor belt, pulling steel blades off the belt and placing them on the low heat belt. One of the blades fell off the quench belt onto the floor. The employee bent over to pick the blade up off the floor when another blade fell off the quench belt and struck them on the top of their head. The employee was hospitalized with a brain bleed.
An employee was operating a 32-ton mechanical power press performing a presetting function when a finger on his left hand was caught in the press and the fingertip was amputated.
An employee was charging a gas spring to pressure when the gas spring blew apart, injuring his right hand, left hand, and abdomen. The employee suffered the amputation of three fingers on his right hand and was hospitalized.
An employee was conducting a measurement setup on a parabolic eye forming apparatus. During the setup process, the forming assembly cycled and the employee's left index finger was crushed between the forming assembly and the die block. The employee sustained a laceration and fracture to the left index finger that resulted in medical amputation of the fingertip.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.