KIOWA LINE BUILDERS

Struck by discharged object or substance · Puncture wounds, except gunshot wounds

Federal OSHA recorded a severe workplace injury at KIOWA LINE BUILDERS, 801 State Route 5, TIPTON, MISSOURI 65081 on — Puncture wounds, except gunshot wounds, affecting the hand(s), unspecified.

A lineman was working in an aerial lift when a leaking, broken hydraulic line injected fluid into his hand. He was hospitalized.

Hospitalized Hand(s), unspecified Lubricating greases, cutting oils

KIOWA LINE BUILDERS

An employee was dead-ending an electrical connection. After coming down in the bucket truck the employee realized he left a nylon strap on the upper portion of the pole. While retrieving the strap the employee made contact with an energized line resulting in a shock. The employee sustained burns to the left arm, back, and chest.

KIOWA LINE BUILDERS

An employee building high-voltage overhead powerlines came in contact with 7,200 volts from a live jumper line. The employee was hospitalized for an electrical shock and burns.

View KIOWA LINE BUILDERS's full OSHA safety record →

Robinson Renovation & Custom Homes, Inc.

An employee was installing wood trim surrounding a skylight inside a home. While holding a piece of trim in it's desired location, his pneumatic nail gun discharged, sending a 3/4-inch pin nail into his left forearm.

Weldship Corporation

An employee removed a safety valve on a trailer that unknowingly contained nitrogen gas. The gas released from the trailer and pushed the employee backward off a scaffold approximately 10 feet before they struck a garage door, resulting in a pelvic injury.

Conner Industries, Inc.

An employee was sitting at her workstation when a nail gun malfunctioned and shot a nail into her left leg. She suffered a puncture and blood vessel injury and was hospitalized.

HK Cooperative, Inc.

On November 25, 2023, an employee was using a high-pressured water hose to perform sewer line cleaning operations. The employee's right little finger and palm were lacerated by pressurized water from the hose.

HPC Industrial Group, LLC

An employee was hydroblasting when they slipped and the pressurized water stream lacerated their left ankle.

Kasparian Underground LLC

An employee was terminating cables in a junction box. A loose ground wire came into contact with the bushing, causing a flash that burned the right side of the employee's face and his right hand.

Viking Utility Construction

An employee was using a bucket truck hoist to raise secondary aerial wiring. The wire made contact with the primary wire, causing an arc flash. The employee suffered burns to both hands and was hospitalized.

Henkels & Mc Coy

An employee was working to move a telephone pole when the pole rolled, causing injury to their hip.

Standard Utility Construction, Inc.

An employee was terminating conductors to buss bars inside the secondary compartment of a single-phase transformer. An arc flash occurred, causing burns to the soft tissue of the employee's face.

Michels Power, Inc.

An employee was securing the claw of a grapple truck to the truck bed. His left little finger was caught between the tie down strap and the rub rail of the truck, resulting in partial amputation of the finger.

WADDELL CONCRETE INC.

An employee was readjusting a safety hook to remove hardware from gang forms when his feet slipped. He fell to the ground, resulting in a broken left arm and wrist.

Dollar Tree

An employee was on a step ladder in a store aisle, making room on shelving for merchandise. She fell from the step ladder to the floor, suffering two fractures in her left leg. She was hospitalized, requiring surgery.

Corrigan Brothers Inc

An employee was closing the side cargo door to a company van. The tip of his finger got caught between the door and the door jamb, resulting in a partial amputation.

Plumb Supply Company

An employee lost his footing while climbing an inclined ladder. He stumbled down one step and was able to stabilize himself by holding the railing and twisting his body, but he suffered an internal abdominal injury and was hospitalized.

JRI INDUSTRIES

An employee was manipulating dies on a brake press. The press caught and crushed the employee's right forearm, resulting in hospitalization.