Federal OSHA recorded a severe workplace injury
at High West Energy Inc, 1010 Chestnut, POTTER, NEBRASKA 69156
on — Fractures, affecting the ankle(s).
Watch High West Energy Inc — freeGet an email when a new federal OSHA severe-injury report for High West Energy Inc is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was driving a four-wheeler. As the employee was leaving the dirt parking lot, the vehicle's tire caught the edge of the concrete. The vehicle tipped and the employee's right foot was caught and twisted between it and the concrete ground. The employee suffered a broken ankle.
An employee was operating a sit-down type of material handling equipment (MHE). They were turning the MHE with the clamp attachment in the air when the MHE fell over onto its right side. The employee's right foot was caught under the battery cover of the MHE. The employee sustained a chemical burn from the battery and a fractured right ankle.
An employee was driving an unloaded forklift outside a building. During a left turn, the forklift drove off the paved area onto an unpaved surface, became unstable, and tipped over. The employee was pinned under the forklift and suffered two broken leg bones and a broken hip.
An employee was trimming tree branches from an aerial lift. As they were maneuvering the aerial bucket lift from inside, the truck drove over soft ground and tipped over. The bucket lift fell to the ground with the employee tied off inside, resulting in rib fractures.
More severe injuries in this industry (NAICS 221122)
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.
An employee (a lineman) was working to restore power by installing a hand line when he contacted a high-voltage device (7,200 volts), resulting in electrical burns to his upper body and hands.
A chain sling failed while a utility pole was being removed. A chain link struck an employee who was operating a front-end loader, puncturing the employee's chest.
An employee was working with an underground crew to troubleshoot a BUD failure. The employee was removing a fuse from the fuse holder when the fuse blew on the riser and an arc flash occurred. The employee was hospitalized with burns to his face, nose, lips, and neck.
An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.
An employee was stacking concrete blocks for a concrete bunker. As a block was swinging into place, the employee's left leg was pinched between two blocks, resulting in injuries to his left heel and lower leg.
An employee was climbing a ladder to inspect a vent in a restaurant dining area. The ladder slid out on the floor and the employee fell approximately 12 feet onto the ladder and the floor. He was hospitalized with a dislocated shoulder and a back injury.
An employee was filtering a fryer with a fryer filter machine. After going around the corner and then returning to the fryers, the employee stepped into the filter machine. The hot oil burned the employee's right ankle, and the employee was hospitalized.
An employee was cleaning out corn from a grain bin. The sweep auger in the bin was activated and caught his trouser leg. His leg was pulled into the auger, which injured his calf and caused leg fractures and lacerations.