105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Lucas Milhaupt

Direct exposure to electricity, unspecified · Electrocutions, electric shocks

Federal OSHA recorded a severe workplace injury at Lucas Milhaupt, 5656 S Pennsylvania Ave, CUDAHY, WISCONSIN 53110 on — Electrocutions, electric shocks, affecting the bODY SYSTEMS.

An employee was showing a maintenance electrician a problem he was having moving a part of a mixing machine. When the injured employee adjusted the ball valves on the equipment the employee received an electric shock and sustained a fractured right scapula, and a fractured and dislocated left shoulder.

Hospitalized BODY SYSTEMS Agitators, mixers-earth, mineral

Lucas Milhaupt

An employee was working with a wire sizing machine when a spool of wire became unraveled and the employee's finger was caught behind the spool resulting in a partial amputation.

View Lucas Milhaupt's full OSHA safety record →

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

Triad Metals International

A load of steel angles was being lowered when the lifting chain hit the load, causing it to slide toward an employee. An angle slid and pinched the employee, catching both of their legs between the beams and an angle. The employee suffered two fractured legs.

Ryder System Inc.

An employee was on the deck of a trailer helping a customer unload tubes. The employee was working to place a cargo strap on the remaining tubes using a winch bar when it slipped off the tubing, causing him to lose his balance and fall headfirst onto the asphalt lot below. The employee suffered a contusion on his forehead, resulting in hospitalization.

EASTERN METAL SUPPLY, INC.

An employee and a customer were unloading two rectangular tubes. The tubes were wrapped together. The plastic wrap was cut so that one tube could be picked up. As the employee was lifting the top tube, the other tube (still connected to the top tube) came down onto his hand and broke two of his fingers. He was hospitalized.

TEXAS PIPE AND SUPPLY COMPANY

An employee was assisting as a forklift got pipe from a pipe rack. The employee was on one of the forklift's forks as it was raised to the top of the rack, a height of about 15 feet. He fell to the ground and suffered a dislocated and fractured right elbow.

United Performance Metals, LLC

On September 23, 2025, at approximately 7:43 p.m., an employee was using a knife to cut poly banding from a metal coil. The knife slipped, causing a laceration to the inside of their left arm at the elbow joint. The employee was hospitalized and required surgery to repair a damaged vein.

RG Professional Carpenter, Inc.

The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.

General Thermodynamics, Inc.

An employee was using a vertical band saw to cut a thick piece of rubber material. While being cut, the material shifted, causing the employee s right hand to contact the moving blade. The employee's thumb was amputated below the knuckle. The employee was hospitalized, undergoing surgery.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

Asher Enterprises, Inc.

An employee was on a ladder, taking measurements for a new gutter installation. The ladder slipped out from under him and both he and the ladder fell to the ground. He was hospitalized with seven broken ribs and a broken clavicle.

Consolidated Electrical Distributors Inc.

An employee was unloading a truck for a delivery job. While moving boxes in the truck, the employee tripped over a pallet and fell out of the truck to the ground, resulting in four broken ribs.