Caught in running equipment or machinery during regular operation · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Encore Wire, 1329 Millwood Road, MCKINNEY, TEXAS 75069
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was starting up a reel on a wire packaging machine when a loop in the wire wrapped around his pinky finger. As the reel was turning to wrap around the drum, the loop tightened around his pinky finger and lacerated it, resulting in a pinky fingertip amputation.
An employee was transferring a load of copper cathode to a furnace when a piece of the cathode slid off a pallet and struck his lower left leg, lacerating it and requiring surgery.
An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.
An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 331420)
An employee was loading an empty reel on the west reel take-up when they noticed that the wire lying on the east reel take-up had over-accumulated on one side of the reel, making it uneven. The employee stopped the east take-up machine and released tension on the wire to correct the lay. As the employee engaged a mechanical rotation function to take up the wire slack, their right little finger was crushed between two separate wire strands on the reel under tension, resulting in a fingertip amputation. The machine was guarded at the time of the incident.
An employee was operating an overhead crane to transport a bundle of copper tubing. He went to lower the load as he was approaching a rack, but the suspended bundle of tubing suddenly jerked in the other direction. The bundle struck a nearby tool cabinet, and the cabinet tipped over. The employee went to prevent it from falling. However, the cabinet still fell over, striking his right arm and briefly pinning it against another object. The employee suffered a fractured right forearm that required hospitalization.
An employee was working to manually clear copper tubes from the turnover rack due to a faulty sensor. As he used his right hand to remove a finished tube from the turnover rack, another tube pushed through the feed line and struck his gloved right ring fingertip. The sharp edge of the copper tube caused a soft tissue amputation to the bottom side of the fingertip.
An employee was cleaning slag from a casting mold at a furnace. The molten copper dropped out of the mold too quickly, reacted with the mold cooling water, and blew out. The molten metal struck his right foot, hand, and torso, causing first-, second-, and third-degree burns.
An employee was working with a drill press when his right glove was caught and pulled into the drill bit. The employee's little fingertip was partially amputated.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.