Caught in running equipment or machinery, n.e.c. · Soreness, pain, hurt-nonspecified injury
At a glance
Federal OSHA recorded a severe workplace injury
at Plaza Extra East, 4 C & D; 4200 Estate Sion Farm, CHRISTIANSTED, VIRGIN ISLANDS 00820
on — Soreness, pain, hurt-nonspecified injury, affecting the multiple body parts, n.e.c..
Final narrative
An employee was operating a bottle blow molding machine when he dropped his cell phone through the front opening of the machine. He activated the machine to move forward and attempted to retrieve his cell phone. While bending over, he touched the stop button, which caused the machine to reverse into the home position. The employee then became pinned when the panel moved into the home position, injuring his left arm and upper torso on the left side.
HospitalizedMultiple body parts, n.e.c.Extruding, injecting, forming, molding machinery, unspecified
Employees were assembling and testing a butterfly valve unit and actuator combo. When the unit was function tested with air, the valve gate closed on an employee's left thumb resulting in a fracture and laceration.
An employee was doing a daily inspection of the sifter screen on a mixer when the mixer line activated. The armature for the screen struck the employee's right wrist. Their wrist was cut and their hand was fractured.
An employee was doing a dry run during the setup of an ice cream machine. The machine indexed and the filler head amputated the employee's left middle finger above the last knuckle.
An employee was on a 3-foot ladder guiding cable onto a spool during installation on an overhead door. As the control box was jogged, the employee's hand was caught between the cable and spool, resulting in a wrist and hand fracture.
More severe injuries in this industry (NAICS 445110)
Employee 1 was investigating a gas odor. While employee 1 was checking the equipment, a gas explosion occurred, resulting in a fire that burned the employee's face. Employee 2 entered the area and a second explosion occurred, causing burns to their face and arms. Employee 2 was hospitalized.
An employee tripped while walking from one store register station to another. Her forehead struck a register, and she suffered fractures to two vertebrae in her neck. She was hospitalized.
An employee was stocking and ordering the meat case on the sales floor when he slipped and fell due to water on the floor. The employee was hospitalized with a fractured ankle and required surgery.
An employee was setting up for a door installation on a three-story building. The employee was moving an aluminum track frame from one condo to the condo next door by using the balcony when they misstepped and fell between balconies. The employee landed on the dirt below and suffered facial fractures.
An employee was replacing a fuel pump on a pickup truck using a transmission jack to lower the fuel tank from the vehicle. When he removed and lowered the tank, the tank caught fire, resulting in burns to his hands, arms, and legs.
An employee was removing concrete forms from a current pour when a form fell from the wall. An intact pin hooked the employee's safety vest and pulled them from the scaffold to the ground, resulting in a bruised chest (lungs).
An employee was driving a cement mixer. It flipped while turning a corner, and the cabin was flattened. The employee was pinned in the cabin and suffered a broken right hand, three broken ribs, and head lacerations.
An employee had attached a crane sling to an 8-inch pipe, and the crane was holding the pipe with minimal tension while bolts were removed from its lower flange. The pipe came loose and knocked the employee off the trailer to the ground 6 feet below. The back of the employee's head struck the trailer after the fall, causing a head injury.