105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Omnicell, Inc.

Caught in running equipment or machinery, n.e.c. · Internal injuries to organs and blood vessels of the trunk

Federal OSHA recorded a severe workplace injury at Omnicell, Inc., 600 Highland Ave., MADISON, WISCONSIN 53792 on — Internal injuries to organs and blood vessels of the trunk, affecting the chest, except internal location of diseases or disorders.

On August 24, 2020, two employees were installing the lower shelf inside a carousel used to dispense prescription medicine. The carousel cycled and its door came down on one employee's chest, causing cracked ribs, a collapsed lung, and hematomas.

Hospitalized Chest, except internal location of diseases or disorders Material and personnel handling machinery, n.e.c.

Omnicell, Inc.

An employee was cleaning an idle roller of a card press. The employee was removing some material when the press tore a tendon in the employee's left index finger.

OMNICELL, INC.

An employee was rewinding the label on a label machine using her left hand. She used her right hand to jog the machine forward and was using her left hand to load the paper on the paper winder. The tip of her glove was caught causing her left hand to wrap around the rotating post and the cardboard core resulting in a left wrist fracture and dislocation as well as a fifth index compound fracture and a fourth index fracture.

View Omnicell, Inc.'s full OSHA safety record →

Scout Surface Solutions

Employees were assembling and testing a butterfly valve unit and actuator combo. When the unit was function tested with air, the valve gate closed on an employee's left thumb resulting in a fracture and laceration.

Gilster-Mary Lee Corporation

An employee was doing a daily inspection of the sifter screen on a mixer when the mixer line activated. The armature for the screen struck the employee's right wrist. Their wrist was cut and their hand was fractured.

Maxwell Paper Products Co

An employee was being trained on a machine when a roller came down on their hand, resulting in a fracture and laceration.

Turkey Hill LLC

An employee was doing a dry run during the setup of an ice cream machine. The machine indexed and the filler head amputated the employee's left middle finger above the last knuckle.

Erie Strayer Company

An employee was on a 3-foot ladder guiding cable onto a spool during installation on an overhead door. As the control box was jogged, the employee's hand was caught between the cable and spool, resulting in a wrist and hand fracture.

GlobiTech, Inc.

An employee was removing parts for replacement during equipment maintenance. His right forearm was exposed to a mixture of silicon dioxide (silica) and trichlorosilane that caused an exothermic reaction and chemical burns. The employee was hospitalized.

Global Foundries, Inc.

An employee's leg went through a part of the floor that was missing a floor tile and he sustained a dislocated shoulder while catching himself.

CONTINENTAL AUTOMOTIVE SYSTEMS

An employee positioned a pallet jack under a mobile TV stand to lift the stand and then clean the wheels. As the employee raised the pallet jack, the TV stand fell forward toward the handle of the pallet jack. The employee went to catch the TV stand and their right thumb became caught between the TV mount frame and the pallet jack, resulting in amputation.

Sinbon Ohio, LLC

An employee was working on the crimp machine when their left middle finger became caught in the machine. The employee sustained the amputation of the fingertip through part of the nail and was hospitalized. The machine was guarded at the time.

Semiconductor Components Industries, LLC

An employee was greasing the belt of an air handler and manually moving the belt when their left ring finger was caught between the belt and the pulley. The employee sustained a severe laceration to the fingertip that resulted in an amputation.

RG Professional Carpenter, Inc.

The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.

General Thermodynamics, Inc.

An employee was using a vertical band saw to cut a thick piece of rubber material. While being cut, the material shifted, causing the employee s right hand to contact the moving blade. The employee's thumb was amputated below the knuckle. The employee was hospitalized, undergoing surgery.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

Asher Enterprises, Inc.

An employee was on a ladder, taking measurements for a new gutter installation. The ladder slipped out from under him and both he and the ladder fell to the ground. He was hospitalized with seven broken ribs and a broken clavicle.

Consolidated Electrical Distributors Inc.