Ignition of vapors, gases, or liquids · Second degree heat (thermal) burns
At a glance
Federal OSHA recorded a severe workplace injury
at Amspec LLC, 5237 Halls Mill Rd, MOBILE, ALABAMA 36619
on — Second degree heat (thermal) burns, affecting the hand(s), unspecified.
Final narrative
An employee was running a liquefied petroleum gas (LPG) standard with laboratory equipment when the equipment was knocked off the counter, causing the quick connect to fail. LPG then released and was ignited by the equipment's heating element. The employee received first and second degree burns on the right and left hands.
HospitalizedHand(s), unspecifiedPetroleum fuels, distillates, and products, n.e.c.
An employee was boarding a barge. As he stepped onto the gangway, it shifted and the handrail he was using collapsed, causing him to fall and strike his right knee against the gangway. His patellar tendon was torn.
An employee was cleaning a cordless drill. As they applied brake fluid to the drill and pulled the trigger, the fluid ignited. The employee suffered burns to the face, hands, and arms.
An employee was spraying glue to the floor of an enclosed cargo trailer. The fumes made contact with the heater causing a flash fire. The employee suffered burns to their face and right hand.
An employee was replacing a valve in the gas line to the fryer. The shutoff valve malfunctioned resulting in a gas leak that then ignited. The employee sustained burns requiring hospitalization.
An employee was operating a horizontal belt sanding machine that rotates a metal sanding belt. The employee switched hands while the belt transitioned from left to right. When the machine's speed was adjusted, the employee s left hand was pulled into the machine and crushed. The employee was hospitalized and required surgery.
An X-ray machine had lost power and an employee went to replace the power supply. While replacing a cable on the power supply assembly, the employee's right hand contacted the grounding terminals coming out of the back of the power supply assembly and they received an electric shock. The employee was hospitalized.
On March 19, 2025, an employee was retrieving a medical specimen from the back of a vehicle. When he turned to enter the building, he either tripped over something or lost his footing and fell due to an incline in the pavement. The employee was hospitalized with a head abrasion and injuries to his right shoulder and right hip.
Employees were pulling a chemical sample from a device (sample port). The sample wouldn't come out because there were two samples in the port. The employees then turned off and deenergized the machine to 0 pounds per square inch. They unscrewed the top of the machine to retrieve the stuck samples when a small amount of pressure caused liquid to squirt out and onto one of the employee's face shields as the lid was removed. The employee was hospitalized due to chemical exposure.
An employee was walking around a boiler recovery tank when they stepped into an uncovered U-drain filled with hot water. The employee sustained second-degree burns to their right leg and the top of their foot.
An employee was traveling down the maintenance aisle of a warehouse on a single-pallet front rider jack. The jack malfunctioned, causing the brakes to apply; the employee fell forward onto the concrete warehouse floor. The employee suffered an injury to the left leg and was hospitalized, requiring surgery.
An employee was operating a metal roller machine to roll a small piece of metal. The employee's right index finger became caught between the metal and the machine, and the fingertip was amputated.
An employee was directing a truck driver to a dump site when the truck's peanut trailer slipped off the kingpin. As the trailer fell, a ladder attached to it lacerated the employee's ear. The employee was hospitalized.
An employee was unloading a forklift from a trailer to the ground. The employee was climbing down the ladder of the trailer when their foot slipped through one of the rungs, causing them to fall backward onto the forklift forks. The employee was hospitalized for fractured ribs.