Struck by object falling from vehicle or machinery-other than vehicle part · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Wieland Rolled Products North America LLC, 250, EAST ALTON, ILLINOIS 62024
on — Fractures, affecting the upper and lower limb(s).
Watch Wieland Rolled Products North America LLC — freeGet an email when a new federal OSHA severe-injury report for Wieland Rolled Products North America LLC is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was attempting to realign a floor plate in the metal transfer run when a coil of brass product fell off the buggy, pinning the employee's lower leg. The employee sustained a fractured lower leg and wrist and a laceration on the back of the lower leg.
HospitalizedUpper and lower limb(s)Reels, rolls, spools, coils, cones
More severe injuries at Wieland Rolled Products North America LLC
An employee was moving a copper coil to a staging area. This movement utilizes a machine-driven, slow-moving coil car running along a track. When the coil reached the employee's location, the coil pinned them to the guard rail, resulting in burns and a pelvis fracture.
A tractor trailer driver climbed into the driver's seat of their truck, set down their lunch box and hat, and started to get back out of the truck to get some gloves. The employee fell to the ground and suffered a compound fracture to the wrist that required surgery.
An employee was measuring the thickness of a brass strip as it was being fed into a press. A micrometer the employee was using was pulled into a 4-inch gap at the press opening, taking the employee's right hand with it. The employee's little finger was partially amputated.
An employee was transporting an 800-pound die on a cart from the tool room. The employee was pulling the cart when it struck a metal plate on the floor. This caused the cart to tip forward and the die to slide off the cart. The die struck the employee's left foot and their second toe was amputated.
An employee was using a forklift to load pallets of product on a trailer. He exited the forklift to adjust a pallet by hand. The pallet fell on him, resulting in an injury to the left leg.
An employee was lifting a 500-pound steel counterweight off a pallet using a magnetic hold jib crane. The counterweight detached from the crane and the employee sustained a left foot/toe fracture that required surgery.
An employee was using a pipe wrench to turn a 42-foot-long steel pipe on jack stands to weld the bottom portion. The pipe fell off the stands, striking the injured employee on his left shin. The employee sustained a left leg fracture at the shin area as well as a tibia fracture that required surgery.
More severe injuries in this industry (NAICS 331420)
An employee was loading an empty reel on the west reel take-up when they noticed that the wire lying on the east reel take-up had over-accumulated on one side of the reel, making it uneven. The employee stopped the east take-up machine and released tension on the wire to correct the lay. As the employee engaged a mechanical rotation function to take up the wire slack, their right little finger was crushed between two separate wire strands on the reel under tension, resulting in a fingertip amputation. The machine was guarded at the time of the incident.
An employee was operating an overhead crane to transport a bundle of copper tubing. He went to lower the load as he was approaching a rack, but the suspended bundle of tubing suddenly jerked in the other direction. The bundle struck a nearby tool cabinet, and the cabinet tipped over. The employee went to prevent it from falling. However, the cabinet still fell over, striking his right arm and briefly pinning it against another object. The employee suffered a fractured right forearm that required hospitalization.
An employee was working to manually clear copper tubes from the turnover rack due to a faulty sensor. As he used his right hand to remove a finished tube from the turnover rack, another tube pushed through the feed line and struck his gloved right ring fingertip. The sharp edge of the copper tube caused a soft tissue amputation to the bottom side of the fingertip.
An employee was cleaning slag from a casting mold at a furnace. The molten copper dropped out of the mold too quickly, reacted with the mold cooling water, and blew out. The molten metal struck his right foot, hand, and torso, causing first-, second-, and third-degree burns.
An employee was working with a drill press when his right glove was caught and pulled into the drill bit. The employee's little fingertip was partially amputated.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was driving a boom lift (in the lowered position) in an exterior dock area. The lift s left wheels rolled onto base plates that covered a 3-foot-deep sump pit. The base plates failed, and one side of the lift dropped. The employee's left leg was caught under the lift basket, and he suffered a fracture to the lower leg including the ankle.