Fall on same level while climbing stairs, steps, or curbs · Soreness, pain, hurt-nonspecified injury
At a glance
Federal OSHA recorded a severe workplace injury
at Terumo BCT, 10811 West Collins Ave, LAKEWOOD, COLORADO 80215
on — Soreness, pain, hurt-nonspecified injury, affecting the multiple head locations.
Final narrative
An employee tripped on a curb and fell. She suffered a blunt-force injury to the left side of the face (in the eye/ear area) and a bruised left wrist.
A cooling tower fan had stopped working. The breaker feeding the fan had been turned off, and an employee was investigating the problem with the fan. The subpanel was connected to a variable-speed motor; a circuit overloaded and an arc flash burned the employee's left arm, forearm, and hand.
An employee was assembling parts in a clean room while wearing a new smock with a tightly woven hood. She became faint (possibly due to overheating), lost consciousness, and fell to the floor, breaking her hip. She was hospitalized, undergoing surgery.
A nurse was visiting the home of a patient for requested treatment. She tripped on her gown while going up the steps to the property, falling and fracturing her left femur.
An employee was walking up an escalator that was out of service when they tripped on a step, fell, and suffered a closed fracture to the right femur as well as a dislocated right patella.
More severe injuries in this industry (NAICS 339113)
An employee was running a can coder that runs on a conveyor belt. The employee was stepping over the rollers when she slipped or tripped. She fell to the floor and sustained a fractured right ankle, requiring surgery.
On August 25, 2025, at approximately 4:47 p.m., an employee was manually raising a malfunctioning loading dock door when his right middle finger was caught in a pinch point, resulting in a fingertip amputation.
An employee was replacing the heating element on a small steam sterilizer when they were burned by hot water and steam on their arms, chest, abdomen, and thighs.
A STERIS installer had uncrated a drying cabinet and was working with a STERIS installation specialist to tilt the cabinet up. As the unit was being tilted up, it slid forward, causing both employees to lose balance. The drying cabinet fell on the installer s right middle finger, resulting in an open fracture and amputation of the distal fingertip.
An employee was operating an automated bagging and packaging machine to bag hydrocolloids. A bag was stuck in the machine. As the employee was removing it, the blade amputated the top of their right index finger.
An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.
A concrete batch plant operator was assisting with clearing spoil piles using a skid steer. The skid steer backed into a stationary screen plant. The employee's left little finger was crushed between the controls of the skid steer and the screen plant, resulting in a fracture and laceration. The employee's finger was surgically amputated.
An employee was standing on an extension ladder, using a torquing tool to remove bolts that secured blades to a rotor. When the torquing tool activated, its reaction arm came around and pinched the employee's right middle finger against a lifting eye. His fingertip was amputated.