105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

The Bryce Company, LLC

Caught in running equipment or machinery during regular operation · Fractures

Federal OSHA recorded a severe workplace injury at The Bryce Company, LLC, 450 South Benton St, GEORGETOWN, ARKANSAS 72143 on — Fractures, affecting the foot (feet), n.e.c..

An employee was assisting a new employee with laminator machine startup. The extruder is on a carriage that can be moved along tracks in the floor. As the extruder was being moved into the machine, the injured employee stepped into the area to assist the new employee and then turned to move out of the area. As he turned, his foot was pinned between the extruder carriage and the floor stop, resulting in non-displaced fractures of the second and third metatarsals of the left foot. He was hospitalized.

Hospitalized Foot (feet), n.e.c. Extruding, injecting, forming, molding machinery, n.e.c.

The Bryce Company, LLC

A machine operator was completing a job change at their machine when a cylinder roller (anilox) did not properly align in the machine. The operator went to the cylinder area to see what was keeping the cylinder from properly aligning. As the operator leaned toward the cylinder to inspect, the cylinder dropped into the correct cradle position. When this occurred, the operator's left hand was positioned between the cylinder and the cradle and their index fingertip was crushed, resulting in a partial amputation.

The Bryce Company, LLC

An employee was putting a cylinder in a deck when the cylinder would not set into the deck properly due to a misaligned bearing. He used a pry bar to raise the cylinder and realign the bearing. He was attempting to align the bearing cap when the pry bar slipped and the cylinder fell, causing the cylinder bearing cap to close on his left index finger. He suffered a left index finger partial distal phalanx amputation.

View The Bryce Company, LLC's full OSHA safety record →

Pall Corporation

An employee was operating a machine when a wire pulled his right glove resulting in amputation of the index and middle fingertips.

Koch Foods of Cincinnati

An employee was grinding chicken when their right index fingertip was caught in the grinder and amputated.

Stella-Jones Corporation

An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.

Mack Manufacturing, Inc.

An employee was passing through a large metal door when the door closed on the employee, resulting in a cracked rib.

Nutmeg Container Corporation

An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.

DimcoGray Corporation

An employee was operating a drill and tap machine. He was placing a part with his right hand and removing a part coming in on the left side. He saw a part that was crooked and went to straighten it. The machine clamped down on his left index finger, degloving the top part of the finger and resulting in a partial amputation.

Greatmats.com Corporation

An employee was performing maintenance on a roll cutting machine in a warehouse. The employee was removing excess grease from the bearings when the machine's chain caught their right index finger. The fingertip was amputated by the chain and sprocket.

Shumard Corporation

During fiberglass work, an employee mixed a methyl ethyl ketone peroxide (MEKP) catalyst with a cobalt chemical that they thought was a dye. A chemical reaction occurred, resulting in an explosion. The employee sustained second-degree burns on his back and a blister on his right arm.

Toledo Molding & Die, Inc.

An employee was walking when she tripped over a box on the ground and fell. The employee was hospitalized with a severe dislocation to the hip and leg that required surgery.

United Window & Door Manufacturing, Inc.

An employee was cutting material on a straight saw when the blade lacerated her right index finger. The employee was hospitalized.

NATIONAL MILL MAINTENANCE, LLC

An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.

The Goodyear Tire & Rubber Company

On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.

Big River Steel, LLC

An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.

American Tile & Marble Co., Inc

An employee was helping two other employees to push a pallet of tile on a loading dock. He suffered a broken fibula and was hospitalized.

Johnson Industrial Coatings, LLC.

On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.