105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Thacker Construction of Northwest Florida

Jack-knifed or overturned, nonroadway · Amputations

Federal OSHA recorded a severe workplace injury at Thacker Construction of Northwest Florida, 700 Myrick St, PENSACOLA, FLORIDA 32505 on — Amputations, affecting the lower leg(s).

An employee was building a re-engineered boat storage building using a telehandler. The employee was unloading cables from a semi-truck using the telehandler when cables shifted, causing the telehandler to start tipping. The band holding the cables broke and the vehicle fully overturned. The employee's left leg was pinned by the vehicle, resulting in a lower leg amputation.

Hospitalized Amputation Lower leg(s) Industrial vehicle, material hauling and transport-powered, n.e.c

DHL Supply Chain

An employee was operating a sit-down type of material handling equipment (MHE). They were turning the MHE with the clamp attachment in the air when the MHE fell over onto its right side. The employee's right foot was caught under the battery cover of the MHE. The employee sustained a chemical burn from the battery and a fractured right ankle.

Perfect North Slopes

An employee was driving a snowmobile when it flipped over. The employee suffered a broken rib.

Olympic Steel, Incorporated

An employee was driving an unloaded forklift outside a building. During a left turn, the forklift drove off the paved area onto an unpaved surface, became unstable, and tipped over. The employee was pinned under the forklift and suffered two broken leg bones and a broken hip.

Core Scientific, Inc

An employee was riding in a utility task vehicle when it overturned. The employee sustained a broken leg.

West Tree Service, Inc.

An employee was trimming tree branches from an aerial lift. As they were maneuvering the aerial bucket lift from inside, the truck drove over soft ground and tipped over. The bucket lift fell to the ground with the employee tied off inside, resulting in rib fractures.

Burke Builders Inc

An employee was cutting cabinet trim using a table saw when four fingers on his left hand were severed, resulting in hospitalization and amputation.

Hobby Lobby Stores, Inc.

The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.

Cross Management Corp.

An employee was installing insulation in a wall when she tripped on a hole (12" deep) and fell, hitting her head on the concrete floor. The employee sustained fractures to her leg and wrist, and lacerations to her head. The employee was hospitalized.

STEEL STRUCTURES AMERICA INC

An employee was loading a 4-inch wooden door into a pickup truck when he felt a pop in his right side behind his shoulder blade. He was hospitalized later that day and underwent surgery, having suffered a collapsed right lung.

Trejo Concrete & Steel, LLC

An employee was operating a power drill when it slipped. The drill bit punctured the employee's hand and they were hospitalized.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.