Vestas Wind Technology, Inc.

Other fall to lower level, unspecified · Fractures

Federal OSHA recorded a severe workplace injury at Vestas Wind Technology, Inc., 43820 CR 86, MATHESON, COLORADO 80830 on — Fractures, affecting the hip(s).

An employee was descending on the inside of a turbine tower when he fell to the next lower level, resulting in a right hip fracture.

Hospitalized Hip(s) Ladders-fixed

Providence Place Cinemas 16 and IMAX

An employee was fixing ceiling tiles while working from a ladder when they fell to the floor and sustained a hip fracture.

DC Janitorial & Cleaning of Pensacola, Inc.

An employee was on an A-frame ladder retrieving materials from a shelf. He slipped and fell and his leg got caught in the ladder rungs, breaking his left tibia.

The Boldt Company

An employee was unloading materials from a flatbed trailer when they fell from the trailer and landed on the ground. The employee sustained a fractured left leg.

HD Supply Facilities Maintenance

An employee was unloading appliances at a customer location for delivery. The employee was moving a water heater to be placed on the liftgate when he stepped backward and fell to the ground. The employee sustained rib and back injuries.

Freedom Solar LLC

An employee was coming down a portable ladder when they slipped and fell to the ground, resulting in a right forearm fracture.

Vestas-American Wind Tech

Two employees were removing a circuit breaker. The injured employee was using wrenches in the removal process. One of the wrenches contacted an adjacent door, resulting in an arc flash. The employee suffered burns to their neck, face, and ear, as well as momentary vision loss due to the flash.

Spark Power Corp

An employee was ascending the wind tower when their right arm was caught between the lift and the ladder. The employee sustained a right elbow injury and was hospitalized.

Acciona Energy North America Corporation

On 3/27/2025, at 9:57 AM, an employee was performing switching work including installing electrical grounds when an arc flash occurred. Personal protective equipment (PPE) was worn at the time, including an arc flash hood, shirt, and pants. The employee suffered burns and was hospitalized.

Invenergy Services LLC

An employee was cleaning dirt out of a contactor using a hand-held blower and contact cleaner. An arc flash occurred, and the employee sustained burns to the right side of their face and both hands.

GD Energy Services - Wind, Inc.

On February 16, 2025, an employee was descending a ladder on the third deck after completing rigging at a wind farm. Their left foot slipped on the penultimate rung and their leg became wedged between the ladder rungs and a horizontal bracket. The employee then landed on the second deck resting platform, resulting in a leg fracture above the ankle.

ABC Supply Company

An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.

Burke Builders Inc

An employee was cutting cabinet trim using a table saw when four fingers on his left hand were severed, resulting in hospitalization and amputation.

Circle Graphics, Inc.

An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.

FLATIRON CONSTRUCTION CORP.

A concrete batch plant operator was assisting with clearing spoil piles using a skid steer. The skid steer backed into a stationary screen plant. The employee's left little finger was crushed between the controls of the skid steer and the screen plant, resulting in a fracture and laceration. The employee's finger was surgically amputated.

Takkion OPS Management

An employee was standing on an extension ladder, using a torquing tool to remove bolts that secured blades to a rotor. When the torquing tool activated, its reaction arm came around and pinched the employee's right middle finger against a lifting eye. His fingertip was amputated.