Contact with hot objects or substances · Heat (thermal) burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Project Services LLC, 1049 Triad Court, AIKEN, SOUTH CAROLINA 29808
on — Heat (thermal) burns, unspecified, affecting the head and neck.
Final narrative
An employee was working on a boiler and spraying water to cool down a scaffold when hot ash from the boiler precipitator came into contact with their face and neck, resulting in burns.
HospitalizedHead and neckScrap, waste, debris, n.e.c.
An employee connected a steam line to a hose to clean equipment when the fitting broke loose. They were struck by steam in the left inner thigh, resulting in burns that required hospitalization.
An employee was making tea when she noticed tea grinds were collecting on the side and water was no longer dripping through the funnel. The employee was checking the funnel when boiling water and tea grinds spilled onto the left side of her body. The employee sustained burns to her neck, back, and arm.
An employee had turned off the ball valve on a waterpipe system and was removing the plug when the coupling system attached to the strainer came apart. Hot water sprayed on his arm and back, resulting in first- and second-degree burns that required surgery.
An employee was using a shovel to remove waste vermiculite from molten zinc. The metal had been placed in a bin and partially hardened. The employee broke through the partially hardened metal; still-molten metal flowed to the employee's steel-toed right boot and entered through the cloth boot tongue. The employee suffered a third-degree burn to the right foot and was hospitalized.
More severe injuries in this industry (NAICS 541380)
An employee was operating a horizontal belt sanding machine that rotates a metal sanding belt. The employee switched hands while the belt transitioned from left to right. When the machine's speed was adjusted, the employee s left hand was pulled into the machine and crushed. The employee was hospitalized and required surgery.
An X-ray machine had lost power and an employee went to replace the power supply. While replacing a cable on the power supply assembly, the employee's right hand contacted the grounding terminals coming out of the back of the power supply assembly and they received an electric shock. The employee was hospitalized.
On March 19, 2025, an employee was retrieving a medical specimen from the back of a vehicle. When he turned to enter the building, he either tripped over something or lost his footing and fell due to an incline in the pavement. The employee was hospitalized with a head abrasion and injuries to his right shoulder and right hip.
Employees were pulling a chemical sample from a device (sample port). The sample wouldn't come out because there were two samples in the port. The employees then turned off and deenergized the machine to 0 pounds per square inch. They unscrewed the top of the machine to retrieve the stuck samples when a small amount of pressure caused liquid to squirt out and onto one of the employee's face shields as the lid was removed. The employee was hospitalized due to chemical exposure.
An employee was walking around a boiler recovery tank when they stepped into an uncovered U-drain filled with hot water. The employee sustained second-degree burns to their right leg and the top of their foot.
An employee delivered a package. On her way back to her vehicle she was attacked by two dogs that came from around a corner. She was hospitalized with dog bites.
The injured employee was standing by the controls for the electric spud system on the barge, preparing to raise the spuds. Meanwhile, an excavator was moving a mat on the deck. As the excavator swung from port to starboard, it's counterweight struck the injured employee s shoulder, causing them to lose balance and fall against the spud controls. The employee sustained bruises and contusions to their right shoulder and chest.
A technician was operating a crane hoist to lift/remove a cylinder head from the main engine (port). The load was lifted at an angle, causing the cylinder head to get stuck on the cylinder head studs. When it became free from the studs, the cylinder head swung. It struck the technician and caught them against the cabinet door. This resulted in an amputation of their left index fingertip at the distal knuckle.
An employee was securing a power cord to a refrigerated truck container. A truck started backing up to connect with the container and the employee was pinned between the tires of the container and the bolster of the truck, resulting in a fractured leg.