105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Prysmian Cables and Systems USA, LLC

Caught in or compressed by equipment or objects, unspecified · Amputations

Federal OSHA recorded a severe workplace injury at Prysmian Cables and Systems USA, LLC, 54 Jacket Line 9975 HWY 80East, SCOTTSVILLE, TEXAS 75688 on — Amputations, affecting the finger(s), fingernail(s), n.e.c..

An employee was checking cable wires and went to place a cable back on the belt. When the employee pulled the cable, his right thumb got caught between the cable and the belt, resulting in an amputation to the distal phalanx. A guard was in place on the capstan door at the time.

Hospitalized Amputation Finger(s), fingernail(s), n.e.c. Machinery, unspecified

Prysmian Cables and Systems USA LLC

An employee opened a service door for a spooler house draw bench and leaned inside to change a bobbin. The door then closed on her, striking and injuring her neck and knee. The employee was hospitalized.

Prysmian Cables and Systems USA, LLC

An employee was entering the building and slipped on a wet floor by the time clock. The employee struck a wall and fell onto the concrete floor. The employee's left distal femur (knee) was fractured.

View Prysmian Cables and Systems USA, LLC's full OSHA safety record →

N. S. Giles Foundations, Inc.

An employee was changing mud cups in the hopper cylinders of a concrete pump truck. The cylinders moved and three of the employees fingers were amputated.

Weld Mech, Inc.

An employee was standing on the rig floor next to a polishing unit. His hand was placed on the polishing unit when the pump was lowered, resulting in amputation of their right thumb, ring, and middle fingertips.

Axium Packaging LLC

An employee was using air to blow out the air wash to the blender and grinder station. As the employee reached to verify that the air wash was clean, the unit pinched and amputated their fingertip.

PanTerra Energy

An employee was retrieving a lost drill pipe with a lifting bail when their left thumb got pinched between the table and handle of the lifting bail while trying to re-thread the pipe to lift it out. The employee suffered an amputation to the left thumb.

Graphic Packaging International

An employee was removing a core chuck from a stationary roll when their right ring finger was pinched between the chuck and the roll. The employee's fingertip was amputated.

Encore Wire Corporation

An employee was loading an empty reel on the west reel take-up when they noticed that the wire lying on the east reel take-up had over-accumulated on one side of the reel, making it uneven. The employee stopped the east take-up machine and released tension on the wire to correct the lay. As the employee engaged a mechanical rotation function to take up the wire slack, their right little finger was crushed between two separate wire strands on the reel under tension, resulting in a fingertip amputation. The machine was guarded at the time of the incident.

Mueller Copper Tube

An employee was operating an overhead crane to transport a bundle of copper tubing. He went to lower the load as he was approaching a rack, but the suspended bundle of tubing suddenly jerked in the other direction. The bundle struck a nearby tool cabinet, and the cabinet tipped over. The employee went to prevent it from falling. However, the cabinet still fell over, striking his right arm and briefly pinning it against another object. The employee suffered a fractured right forearm that required hospitalization.

Hailiang Copper Texas Inc

An employee was working to manually clear copper tubes from the turnover rack due to a faulty sensor. As he used his right hand to remove a finished tube from the turnover rack, another tube pushed through the feed line and struck his gloved right ring fingertip. The sharp edge of the copper tube caused a soft tissue amputation to the bottom side of the fingertip.

Mueller Copper Tube

An employee was cleaning slag from a casting mold at a furnace. The molten copper dropped out of the mold too quickly, reacted with the mold cooling water, and blew out. The molten metal struck his right foot, hand, and torso, causing first-, second-, and third-degree burns.

New England Wire Products, Inc

An employee was working with a drill press when his right glove was caught and pulled into the drill bit. The employee's little fingertip was partially amputated.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC