Struck by other falling object n.e.c. · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Crown Lift Trucks, 401 General Drive, ARDMORE, OKLAHOMA 73401
on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).
Final narrative
An employee was installing a dock leveler at a customer location. Cardboard was under the plate and a pry bar was used to lift the dock plate to remove the cardboard. The pry bar shifted and the dock plate fell on the employee's left ring and middle fingertips resulting in amputations.
Amputation Finger or thumb tip(s), nail(s) Loading docks, dock plates
An employee was operating a lift truck when it struck a stationary lift truck. His left thumb was pinched between the two lift trucks, resulting in a partial amputation.
On June 6, 2025, an employee was performing maintenance on a vertically-stored dock leveler. After completing the hydraulic repair, the employee went to exit the work area when their pant leg got caught on the bumper of the dock leveler. This caused the employee to lose their balance and fall out of the open dock door, approximately 37.5 inches. The employee sustained a lower left leg fracture.
An employee was manually moving a forklift battery in its compartment when her right index finger was pinched between the battery and the top of the compartment. The employee sustained a fingertip amputation.
On April 30, 2024, while at a customer location loading equipment onto a flatbed trailer for transport, an employee was injured when the trailer settled downward and pinched the employee's left foot between the equipment being loaded and the dock plate. The foot was fractured.
On September 25, 2023, a forklift maintenance technician was removing a fork from the lift truck when the fork slipped from the employee's grip. His finger was pinched between the fork and the carriage, resulting in an amputation of the right ring finger just below the nail.
The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.
An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
An employee was climbing a ladder to inspect a vent in a restaurant dining area. The ladder slid out on the floor and the employee fell approximately 12 feet onto the ladder and the floor. He was hospitalized with a dislocated shoulder and a back injury.
An employee was operating a lift truck when it struck a stationary lift truck. His left thumb was pinched between the two lift trucks, resulting in a partial amputation.
An employee was disassembling a pressurized unit using a driver drill. When the unit was disassembled, it caused a kickback from the tube head, causing the drill to strike the employee's left forearm. They sustained a diaphyseal fracture to their left radius and ulna, which required surgery.
After repairing a piece of industrial equipment, an employee had brake-cleaning liquid on his gloves. A lighter ignited the liquid, and the employee's hands were severely burned.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was working in the food service warehouse when he experienced chest pain, difficulty breathing, and lost consciousness. The employee sustained carbon monoxide poisoning.
An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.
An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.
An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.