105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Mannington Mills, Inc.

Hitting, kicking, beating by other person n.e.c. · Intracranial injuries with skull fractures

Federal OSHA recorded a severe workplace injury at Mannington Mills, Inc., 1844 US Highway 41 SE, CALHOUN, GEORGIA 30703 on — Intracranial injuries with skull fractures, affecting the Brain.

On March 13, 2024, two employees got into an altercation where the injured employee received multiple punches to the head and was knocked unconscious. They were hospitalized with a cracked skull.

Hospitalized Brain Co-worker or work associate of injured or ill worker unspecified

Mannington Mills Inc.

An employee was performing startup activities on a print line. The employee was scraping dry ink from the bottom of the doctor blade assembly with a putty knife. The back of her right hand came in contact with the doctor blade, which penetrated her cut-resistant work glove and caused a laceration injury to the back of her hand with damage to a tendon. The employee was hospitalized and required surgery.

Mannington Mills Inc.

An employee was clearing a jam on a line that had caused a belt to come off a roller. The employee slipped and fell 7 feet to the cement floor below, suffering a broken vertebra.

Mannington Mills, Inc.

An employee was climbing down an A frame ladder when the ladder collapsed. The employee suffered two broken ribs.

Mannington Mills, Inc.

An employee was working in a winding station and applying tape to a cardboard core (on a rotating spindle). The employee's gloved hand made contact with the double sided tape pulling her arm into the spindle. The employee sustained multiple fractures to the arm and ribs resulting in hospitalization.

View Mannington Mills, Inc.'s full OSHA safety record →

PVH, Corp.

A temporary employee was punched in the face by another temporary employee. He suffered a laceration to the eye.

Family Dollar 9215

An employee was operating the cash register while customers were attempting to shoplift items. The employee was assaulted by five customers, resulting in fractured ribs requiring hospitalization.

St. Barnabas Hospital, Inc.

An employee was monitoring a psychiatric patient who was walking in the hallway. The patient grabbed the employee by the neck and threw her to the ground. She was hospitalized with an acute superior endplate compression fracture with minimal retropulsion to her T12 vertebra.

HD Supply Facilities Maintenance

An employee was involved in a physical altercation with two temporary employees. The employee was hospitalized with facial injuries and required surgery.

Graver Technologies.

An employee was in a physical altercation with a colleague when his hip was fractured.

NC Works Inc

On September 10, 2025, an employee was working to fix a slipping carpet on a conveyor. He went to lift the carpet and put it back on the top rail when the conveyor belt caught his right hand and a roller subsequently caught his arm. The employee was hospitalized with a broken forearm.

MOHAWK INDUSTRIES, INC.

On July 31, 2025, two employees were walking near a friction wash tank when a rubber gasket on top of the tank blew. Hot water mixed with 50% caustic chemical sprayed out and rained down on the employees. Both employees were brought to an emergency shower and were neutralized with vinegar. One employee was hospitalized with chemical and thermal burns to their upper back and eyes.

Mohawk Industries

On May 27, 2025, an employee had been sweeping the floor around the sort and grind line conveyor. She was wiping down the frame of the conveyor when her right arm was drawn up between the conveyor belt and the snub roller underneath the conveyor. She sustained fractures to her upper and lower arm.

Sprinturf, LLC

On January 29, 2025, an employee was operating an extrusion machine. He put a broken piece of yarn on the secondary roller and his glove was pulled into the nip rollers. The employee's left little fingertip was partially amputated.

Mohawk Industries, Inc.

On December 20, 2024, an employee was preparing to remove the access panel for the rotary valve gear box underneath a washer in polymerization. When he began loosening the bolts from the rotary lock cover, hot water and steam pressure released and caused second-degree burns to the employees stomach, both thighs, and the left calf area.

GS II Building Products, Inc.

An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Alfa Insurance

During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.

EMORY UNIVERSITY HOSPITAL

An employee slipped on condensation on a walkway in a parking garage. She fell and suffered a closed fracture to the neck of the left femur.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.