105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Florida Power & Light Company

Caught, entangled in running powered equipment normal operation · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at Florida Power & Light Company, 6027 Gulf Breeze Parkway, GULF BREEZE, FLORIDA 32563 on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).

An employee was installing a power pole when his finger got caught in the chain that was lifting the pole, resulting in a left ring fingertip amputation.

Hospitalized Amputation Finger or thumb tip(s), nail(s) Elevators, hoists, lifts unspecified

FLORIDA POWER & LIGHT COMPANY

An employee was operating a forklift when the wooden pallet on the forklift struck a material rack, causing the pallet to move and strike the employee in the lower leg. The employee was hospitalized with a fractured leg.

Florida Power & Light Company

Two employees were troubleshooting a post-fire event in a pump room. It was found that one or two nuts were missing from the bolts that secured the loose blow-out panel. One of the two employees placed the blow-out panel back in its original position. As he closed the oil chamber, the vacuum increased. Mixing conditions changed and the oil dispersion exploded. The two employees in front of the blow-out panels sustained severe burns.

Florida Power & Light Company

An employee was installing personal protective grounds at a substation when their hand contacted the end of the ground that was not energized, but induced voltage was created by wind and shocked them. This resulted in a burn on their thumb.

Florida Power & Light Company

An employee was standing on a truck when an overhead powerline broke and landed on the truck. The employee sustained an electrical shock.

Florida Power & Light Company

On September 15, 2021, an employee was pulling wire out from under some bushes when he tripped and fell, resulting in a rib fracture and a punctured lung. He was hospitalized.

View Florida Power & Light Company's full OSHA safety record →

Norflex, Inc.

An employee was operating a metal roller machine to roll a small piece of metal. The employee's right index finger became caught between the metal and the machine, and the fingertip was amputated.

Olympia Food Industries Inc.

An employee was mixing sauce using a sauce barrel mixer when his left little finger was amputated.

Day & Zimmermann Lone Star LLC

An employee was working on a production line. The employee went to retrieve parts that came out of the parts holder, and their left hand became caught between a chain and a sprocket. Three fingers on the hand were amputated.

Ingalls Shipbuilding

An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.

Galaxy Balloons Inc.

An employee was operating a pad printer. The employee's finger was caught in the printer and they suffered a fingertip amputation. The part of the printer that caught the employee's finger was unguarded at the time.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.

Cherokee Electric Cooperative

An employee (a lineman) was working to restore power by installing a hand line when he contacted a high-voltage device (7,200 volts), resulting in electrical burns to his upper body and hands.

Centerpoint Energy Houston Electric, LLC

A chain sling failed while a utility pole was being removed. A chain link struck an employee who was operating a front-end loader, puncturing the employee's chest.

Public Service Electric & Gas

An employee was working with an underground crew to troubleshoot a BUD failure. The employee was removing a fuse from the fuse holder when the fuse blew on the riser and an arc flash occurred. The employee was hospitalized with burns to his face, nose, lips, and neck.

Bright Star Solutions, Inc

An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.