105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Rheogistics LLC

Contact with hot objects or substances · Thermal burns second degree

Federal OSHA recorded a severe workplace injury at Rheogistics LLC, 100 Polymer Drive, PICAYUNE, MISSISSIPPI 39466 on — Thermal burns second degree, affecting the Trunk and other upper extremities.

An employee was mixing up a batch of product when an enhanced reaction occurred that created a wax byproduct. The wax spilled out of the tank and contacted the employee's arm and ribcage, resulting in second-degree burns.

Hospitalized Trunk and other upper extremities Wax

Rheogistics LLC

An employee was listening for a noise at a rotating pulley and belt when their right thumb got caught in the pulley and belt. The employee sustained a partial amputation to the tip of their right thumb.

View Rheogistics LLC's full OSHA safety record →

Spudrock LLC

An employee pulled out a bucket of hot oil from under the fryer. The employee then stood on the table to clean the back wall. He stepped down into the bucket of hot oil, resulting in third-degree burns to his left leg.

Ajinomoto Health and Nutrition North America Inc.

An employee was performing maintenance under a kettle. When he removed a tri-clamp on a transfer line, the hot fat and broth material in the kettle poured out onto his arm. The employee was hospitalized with burns.

APAC-Alabama, Inc.

After completing a run with an oil distributor truck, an employee was working to return (suction) the hot oil to the tank of the truck. When the employee opened one of the valves, hot oil (approximately 385 degrees) sprayed their face, resulting in first-, second-, and third-degree burns.

Cellar Crew LLC

An employee was filtering a fryer with a fryer filter machine. After going around the corner and then returning to the fryers, the employee stepped into the filter machine. The hot oil burned the employee's right ankle, and the employee was hospitalized.

Boise Cascade Wood Products, LLC

An employee was using a water hose to clean debris out of the outfeed of a log conditioning vat. Water began entering the vat from the adjoining vat through a void in the separation wall at the infeed of the vats. As the employee was exiting the vat he had been working in using the access opening at the outfeed, hot water exiting the access opening entered the top of his protective hip wader. It pooled at the bottom of the wader and burned his left foot and ankle.

General Polymeric Corporation

An employee was monitoring a rotary press when his left hand became caught in the machinery. The employee's left middle finger was amputated at the distal interphalangeal joint.

MCM Plastics, Inc.

An employee was sweeping in an area with powdered PVC on the floor and began having difficulty breathing and coughing up blood, The employee was hospitalized for inhalation of PVC.

Lawter Inc.

An employee was working on a pastillator machine, which processes resin-based materials into solid pastilles. His right hand became caught between the feed roller (operating at approximately 350 F) and the cooling belt. The employee s glove and shirt sleeve adhered to his arm due to the heat. The employee sustained third-degree burns to his right hand and forearm, requiring hospitalization and surgery.

AdvanSix, Inc.

An employee was troubleshooting a leak on a low pressure (less than 50 PSI) condensate line in the oxidation area of the plant. He was working to remove insulation around a valve when either the valve or the line failed, and hot condensate contacted his right arm, right abdomen area, and the front of both legs, resulting in second- and third-degree burns.

Rochling Machined Plastics

An employee was replacing a fan on a cooling unit. As he went to adjust a pump, the unit caught his right hand and the fan blades severely lacerated his index finger. He underwent a medical amputation to the finger.

Howard Industries Inc.

An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.

Hobby Lobby Stores, Inc.

The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.

Owl's Head Alloys West Point

An employee was going into a trailer to mark product for shipment and the trailer pulled away from the dock. The employee fell out of the trailer, contacted the dock plate, and then fell to the ground. The employee was hospitalized with a punctured lung, fractured ribs, and contusions.

Ingalls Shipbuilding

An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.

Heavy Equipment Movers and Installation, LLC

An employee was operating a gas tugger to lift metal sheeting. His left hand was pulled into the pulley, which crushed his left thumb, resulting in avulsions and other tissue damage. He was hospitalized and required surgery.