QAI LABORATORIES, INC.

Struck by other falling object n.e.c. · Traumatic injuries or exposures unspecified

Federal OSHA recorded a severe workplace injury at QAI LABORATORIES, INC., 8148 Northwest 74th Avenue, MEDLEY, FLORIDA 33166 on — Traumatic injuries or exposures unspecified, affecting the Head unspecified.

An employee was moving a 12' x 12' steel test frame into storage adjacent to a sliding glass door unit. Something struck the bottom of the frame of the sliding glass door unit, causing three sliding door panels to disengage from their test frame. The disengaged panels fell approximately three feet, landing on the employee and forcing him to the ground. His head was caught between the panels and the steel frame resulting in a head injury.

Hospitalized Head unspecified Doors swinging and sliding

RG Professional Carpenter, Inc.

The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.

Rae Corporation

An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.

Red Dot Corporation

An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.

Simon Contractors of South Dakota, Inc.

An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.

RJV Construction

An employee was rigging I-beams. An I-beam slid off the stack of I-beams and fractured the employee's leg.

MAV-TEC Testing Laboratories, LLC

An employee was operating a horizontal belt sanding machine that rotates a metal sanding belt. The employee switched hands while the belt transitioned from left to right. When the machine's speed was adjusted, the employee s left hand was pulled into the machine and crushed. The employee was hospitalized and required surgery.

Boeing (LMTF)

An X-ray machine had lost power and an employee went to replace the power supply. While replacing a cable on the power supply assembly, the employee's right hand contacted the grounding terminals coming out of the back of the power supply assembly and they received an electric shock. The employee was hospitalized.

Cape Cod Healthcare Lab Services

On March 19, 2025, an employee was retrieving a medical specimen from the back of a vehicle. When he turned to enter the building, he either tripped over something or lost his footing and fell due to an incline in the pavement. The employee was hospitalized with a head abrasion and injuries to his right shoulder and right hip.

Agilent Technologies - Frederick, Colorado

Employees were pulling a chemical sample from a device (sample port). The sample wouldn't come out because there were two samples in the port. The employees then turned off and deenergized the machine to 0 pounds per square inch. They unscrewed the top of the machine to retrieve the stuck samples when a small amount of pressure caused liquid to squirt out and onto one of the employee's face shields as the lid was removed. The employee was hospitalized due to chemical exposure.

Applied Technical Services, LLC.

An employee was walking around a boiler recovery tank when they stepped into an uncovered U-drain filled with hot water. The employee sustained second-degree burns to their right leg and the top of their foot.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.