Caught, entangled in running powered equipment normal operation · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Custom Pipe & Fabrication Inc, 3700 West Lake Hamilton Drive, WINTER HAVEN, FLORIDA 33881
on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).
Final narrative
An employee was defacing a pipe when their right index finger went into one of the holes of the flange at the end of the pipe and the fingertip was amputated.
HospitalizedAmputation Finger or thumb tip(s), nail(s) Metal, woodworking, and special material machinery unspecified
More severe injuries at Custom Pipe & Fabrication Inc
An employee was using an overhead crane to pick up a discharge head. His right hand was caught between the lifting apparatus and the discharge head; his right thumb was crushed and bone was broken.
An employee tried to catch a discharge head. It slipped while he tried to catch it and pinched his finger between the strap and the discharge head causing a laceration.
An employee was operating a metal roller machine to roll a small piece of metal. The employee's right index finger became caught between the metal and the machine, and the fingertip was amputated.
An employee was working on a production line. The employee went to retrieve parts that came out of the parts holder, and their left hand became caught between a chain and a sprocket. Three fingers on the hand were amputated.
An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.
An employee was operating a pad printer. The employee's finger was caught in the printer and they suffered a fingertip amputation. The part of the printer that caught the employee's finger was unguarded at the time.
More severe injuries in this industry (NAICS 332996)
An employee was rolling a pipe in a cutting rack and his right little finger became caught between sections of the pipe. The employee's finger was surgically amputated.
An employee was working a vertical bandsaw, cutting half-inch diameter rods into pieces. While using a steel chisel to move the cut pieces, the blade caught his leather glove and pulled his index finger in. The employee sustained an amputation of the finger between the first and second knuckle.
An employee was operating a lathe in a machine shop. The rotating head of the lathe caught the employee's left glove, resulting in a compound open fracture to the left wrist and a laceration to left ear.
An employee was descending the stairs of an oil/gas rig. As he approached the fifth step from the bottom, he slipped. His left ankle was caught in the steps, and he suffered fractures to the left fibula, tibia, and talus. He was hospitalized, requiring surgery.
The injured employee was loading a piece of pipe into a pipe bending machine. He had his right hand on the front of the loader while his left hand supported the piece of pipe in the back. A second operator had slightly clamped around the pipe to keep it in place. The third operator called out a measurement. The machine actuated and caught the the injured employee's left middle and ring fingers between the wiper and the material. The employee required surgery and sustained amputations to the distal joint of the middle and ring fingers.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.