Struck by rolling, sliding, or shifting objects non-running · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Prairie State Generating Company, LLC, 3872 County Hwy 12, MARISSA, ILLINOIS 62257
on — Fractures , affecting the Multiple trunk locations.
Watch Prairie State Generating Company, LLC — freeGet an email when a new federal OSHA severe-injury report for Prairie State Generating Company, LLC is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was manually steadying a piece of switchgear on a forklift when the load shifted and the switchgear struck the employee, resulting in a fractured rib and vertebra.
An employee was using a lathe to machine a part when the employee's glove was caught in the lathe. The employee's hand was then pulled around the lathe, amputating the right middle finger and partially amputating the right index finger.
An employee was using his left hand to push an axle down the line on a raised track work area while holding the remaining axle back with his right hand. A finger on his right hand was caught between the rail and the dust guard of the axle, resulting in a fracture and a laceration.
An employee was moving metal out of a cart. He had removed one piece and was working to move another when the metal shifted. His right ring finger was crushed between the two pieces, and he suffered a partial amputation to the finger pad at the tip.
A load of steel angles was being lowered when the lifting chain hit the load, causing it to slide toward an employee. An angle slid and pinched the employee, catching both of their legs between the beams and an angle. The employee suffered two fractured legs.
Employees were replacing a 24" pig trap door. A strap was shackled on the pig trap door and connected to a forklift. Welders began to cut the door off. An employee was holding onto the door when the cut was finished. The door shifted and caught his fingers, resulting in a hand injury and amputation.
An employee used a crane to set down a bar. The bar measured 9 inches by 16 feet. The strap got stuck under the bar, and the employee asked another employee to jog the roll. The bar rolled and pinched the injured employee's left hand, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 221112)
Employees were pulling three-phase power lines to a power pole. An employee's hand was caught between a pulley and a rope, resulting in amputation of the employee's index, middle, and ring fingertips.
An employee was cutting through two secondary wires with a battery-powered cutting tool. The wires were energized at 120/240 volts; when the employee cut through the insulation around a wire, an arc flash burned the employee's left thumb.
An employee had been preparing material for a lineman at a jobsite and was pulling up wire on a hand line. The employee began to feel ill, suffering from heat illness.
An employee was tamping at the base of a power pole when they were struck by an extendable hot arm that was dropped from an aerial bucket. The employee sustained two broken ribs on the right side, and a pneumothorax on the right side.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was driving a boom lift (in the lowered position) in an exterior dock area. The lift s left wheels rolled onto base plates that covered a 3-foot-deep sump pit. The base plates failed, and one side of the lift dropped. The employee's left leg was caught under the lift basket, and he suffered a fracture to the lower leg including the ankle.