105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Con Edison

Contact with hot objects or substances · Thermal burns second degree

Federal OSHA recorded a severe workplace injury at Con Edison, E 20th St & Irving Pl, NEW YORK, NEW YORK 10001 on — Thermal burns second degree, affecting the Foot (feet) and ankle(s).

An employee used a ladder to descend into a sub-surface structure to investigate a possible leak. As he was stepping down his right foot became submerged in hot water inside a sump pit that was adjacent to the ladder. The employee sustained second-degree burns to his foot and ankle.

Hospitalized Foot (feet) and ankle(s) Water, liquids nonchemical

CON EDISON

An employee was working in a two-person crew to address a steam leak from a flange. A wooden plug was placed into the flange to reduce and mitigate the leak in preparation for the job. The plug dislodged, and the resulting burst of steam burned the employee's right hand, leg, and face. The employee was hospitalized.

Con Edison

An employee was in a manhole when he mis-stepped and lost his balance. His right hand then contacted an energized wire, causing an arc flash that burned his right wrist. He was hospitalized.

Con Edison

An employee became ill after repairing a gas valve in an excavation.

Con Edison

An employee fell from a ladder and injured his right leg.

CON EDISON

Two employees were assaulted by a fellow employee.

View Con Edison's full OSHA safety record →

Spudrock LLC

An employee pulled out a bucket of hot oil from under the fryer. The employee then stood on the table to clean the back wall. He stepped down into the bucket of hot oil, resulting in third-degree burns to his left leg.

Ajinomoto Health and Nutrition North America Inc.

An employee was performing maintenance under a kettle. When he removed a tri-clamp on a transfer line, the hot fat and broth material in the kettle poured out onto his arm. The employee was hospitalized with burns.

APAC-Alabama, Inc.

After completing a run with an oil distributor truck, an employee was working to return (suction) the hot oil to the tank of the truck. When the employee opened one of the valves, hot oil (approximately 385 degrees) sprayed their face, resulting in first-, second-, and third-degree burns.

Cellar Crew LLC

An employee was filtering a fryer with a fryer filter machine. After going around the corner and then returning to the fryers, the employee stepped into the filter machine. The hot oil burned the employee's right ankle, and the employee was hospitalized.

Boise Cascade Wood Products, LLC

An employee was using a water hose to clean debris out of the outfeed of a log conditioning vat. Water began entering the vat from the adjoining vat through a void in the separation wall at the infeed of the vats. As the employee was exiting the vat he had been working in using the access opening at the outfeed, hot water exiting the access opening entered the top of his protective hip wader. It pooled at the bottom of the wader and burned his left foot and ankle.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.

Cherokee Electric Cooperative

An employee (a lineman) was working to restore power by installing a hand line when he contacted a high-voltage device (7,200 volts), resulting in electrical burns to his upper body and hands.

Centerpoint Energy Houston Electric, LLC

A chain sling failed while a utility pole was being removed. A chain link struck an employee who was operating a front-end loader, puncturing the employee's chest.

Public Service Electric & Gas

An employee was working with an underground crew to troubleshoot a BUD failure. The employee was removing a fuse from the fuse holder when the fuse blew on the riser and an arc flash occurred. The employee was hospitalized with burns to his face, nose, lips, and neck.

Bright Star Solutions, Inc

An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.

Garden Angels New York LLC

An employee was cleaning leaves with a backpack blower when he fell from a ladder, resulting in injuries to his head, neck, and back.

Cashless Tolling Constructors

An employee was operating a battery-powered broom to clean demolition debris off the top of the outermost bridge girder. The girder was approximately 11 feet above the demolition scaffold below. The employee fell approximately 8 feet to wind bracing below. The employee was hospitalized with a pelvis/tailbone fracture. Fall protection was in place at the time.

NYU Langone Hospital-Brooklyn

An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.

VILLAGER CONSTRUCTION, INC.

An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.