Roadway collision with other vehicle(s) moving and standing vehicle · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Sturgeon Electric Company, Inc., EB I-70 between Peoria & Havana, DENVER, COLORADO 80238
on — Fractures , affecting the Leg(s) unspecified.
Final narrative
An employee was inside a truck bucket, positioning it to perform maintenance on an overhead sign. A semi-truck in an active lane near the work zone struck the bucket the employee was in, causing the bucket to break and the employee to be ejected. His fall protection harness caught him before he hit the ground. He sustained a fractured left tibia.
An employee was working on runway lights at the airport when they were struck by a water truck. The employee sustained injuries to the arm, shoulder, and torso, requiring hospitalization.
An employee was lubricating the winch drum and cable of a high mast lighting system. The system's halo fell from the cable supporting it and struck the employee, who suffered sprains and bruising.
An employee was on a semi-trailer helping load fiberglass street light poles. The employee fell off the semi-trailer's flatbed when a 35' street light pole weighing approximately 50 lbs. came loose and fell toward the employee. The employee sustained multiple fractures to his pelvis and ribs and was hospitalized.
An employee was troubleshooting a metal door when a gust of wind hit the door, causing it to strike the employee's head. The employee suffered head trauma.
Employees were on a scissor lift, engaged in ceiling repairs within the center tube of the tunnel. A dump truck struck the scissor lift, causing it to topple over. The injured employee was inside the scissor lift when it fell. The employee sustained multiple injuries, including fractures, a head contusion, bulging discs, and lacerations to multiple body parts. The employee was hospitalized.
An employee's telescopic forklift stopped functioning at an intersection of a temporary roadway. The employee leaned over to locate the fuse compartment. Another telescopic forklift backed into the disabled forklift at the intersection. The employee was pinned between both machines. The employee was hospitalized with a fractured lumbar vertebra.
An employee was in their personal vehicle awaiting instructions from the construction contractor on posting traffic cones. The driver of a motor vehicle swerved to avoid a steel plate in the roadway and struck the employee's car. The employee was hospitalized with four fractured ribs.
An employee was working on a signal device while inside the bucket of a bucket truck. A tree service truck with a folded boom arm attached to the top collided with the bottom of the bucket the employee was occupying. This caused the employee to fall from the bucket and strike the pavement below. The employee was hospitalized with multiple injuries.
An employee was parked along the side of a road working on a fiber outage. An automobile driven by an intoxicated person crossed over into the designated work zone and struck the employee's truck. The employee sustained injuries to his chest, lungs, shoulder, and head.
More severe injuries in this industry (NAICS 238210)
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.
An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.
A concrete batch plant operator was assisting with clearing spoil piles using a skid steer. The skid steer backed into a stationary screen plant. The employee's left little finger was crushed between the controls of the skid steer and the screen plant, resulting in a fracture and laceration. The employee's finger was surgically amputated.
An employee was standing on an extension ladder, using a torquing tool to remove bolts that secured blades to a rotor. When the torquing tool activated, its reaction arm came around and pinched the employee's right middle finger against a lifting eye. His fingertip was amputated.