Chinchor Electric Inc.

Roadway collision with other vehicle(s) moving and standing vehicle · Traumatic injuries or exposures unspecified

Federal OSHA recorded a severe workplace injury at Chinchor Electric Inc., 1460 S Leavitt Ave., ORANGE CITY, FLORIDA 32763 on — Traumatic injuries or exposures unspecified, affecting the Multiple body parts unspecified.

An employee was working on a signal device while inside the bucket of a bucket truck. A tree service truck with a folded boom arm attached to the top collided with the bottom of the bucket the employee was occupying. This caused the employee to fall from the bucket and strike the pavement below. The employee was hospitalized with multiple injuries.

Hospitalized Multiple body parts unspecified Boom truck, cherry picker

RAILROAD CONSTRUCTION CO., INC.

Employees were on a scissor lift, engaged in ceiling repairs within the center tube of the tunnel. A dump truck struck the scissor lift, causing it to topple over. The injured employee was inside the scissor lift when it fell. The employee sustained multiple injuries, including fractures, a head contusion, bulging discs, and lacerations to multiple body parts. The employee was hospitalized.

COSTA BROTHERS MASONRY, INC.

An employee's telescopic forklift stopped functioning at an intersection of a temporary roadway. The employee leaned over to locate the fuse compartment. Another telescopic forklift backed into the disabled forklift at the intersection. The employee was pinned between both machines. The employee was hospitalized with a fractured lumbar vertebra.

Flagger Force

An employee was in their personal vehicle awaiting instructions from the construction contractor on posting traffic cones. The driver of a motor vehicle swerved to avoid a steel plate in the roadway and struck the employee's car. The employee was hospitalized with four fractured ribs.

Sturgeon Electric Company, Inc.

An employee was inside a truck bucket, positioning it to perform maintenance on an overhead sign. A semi-truck in an active lane near the work zone struck the bucket the employee was in, causing the bucket to break and the employee to be ejected. His fall protection harness caught him before he hit the ground. He sustained a fractured left tibia.

Charter Communications

An employee was parked along the side of a road working on a fiber outage. An automobile driven by an intoxicated person crossed over into the designated work zone and struck the employee's truck. The employee sustained injuries to his chest, lungs, shoulder, and head.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.

Cherokee Electric Cooperative

An employee (a lineman) was working to restore power by installing a hand line when he contacted a high-voltage device (7,200 volts), resulting in electrical burns to his upper body and hands.

Centerpoint Energy Houston Electric, LLC

A chain sling failed while a utility pole was being removed. A chain link struck an employee who was operating a front-end loader, puncturing the employee's chest.

Public Service Electric & Gas

An employee was working with an underground crew to troubleshoot a BUD failure. The employee was removing a fuse from the fuse holder when the fuse blew on the riser and an arc flash occurred. The employee was hospitalized with burns to his face, nose, lips, and neck.

Bright Star Solutions, Inc

An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.