Struck by suspended or swinging objects n.e.c. · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Norac Additives, LLC, 360 Phillips Road 311, HELENA, ARKANSAS 72342
on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).
Final narrative
An employee was helping to place a scale (approximately 4' x 4') on a work stand. They were aligning the scale when the chain supporting the scale was pulled, causing their left thumb to get caught between the scale and the work stand. The thumb was fractured and the tip was amputated.
An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.
An employee was stacking concrete blocks for a concrete bunker. As a block was swinging into place, the employee's left leg was pinched between two blocks, resulting in injuries to his left heel and lower leg.
An employee was using a crane to move a 44-foot, 3,343-pound I-beam. As the beam was moving west, it straightened out (north to south), beginning to swing south toward the northwest corner of a building. The crane then sent the beam southward, directly toward the corner of the building. The beam caught the tips of the employee's left index, middle, and ring fingers against the building. The last joints of the middle and ring fingers were amputated, and the last joint of the index finger was partially crushed.
An employee was placing a board on top of a bundle of steel tubing. A crane was moving a bundle of steel that struck the employee and caught them against another bundle of steel tubing. The employee sustained a crushing injury and hematoma to the right upper leg.
Employees were using a crane to lower large tree stems and branches while removing limbs and branches from the load. This caused the load to shift and strike an employee in the back, resulting in a hematoma on the lower left part of their back and a fractured ankle.
More severe injuries in this industry (NAICS 325199)
Two employees were lifting a roll of steel poly bar (50 inches and approximately 150 pounds) from ground level to a height of 4 feet at the 66-inch rubber calendar. One employee dropped the roll, resulting in the poly bar contacting the injured employee's right knee. The employee was hospitalized with fractured right patella.
Employees were loading a 295-pound transformer onto a pickup truck using a forklift. The injured employee was acting as the spotter. The transformer hit the tailgate of the pickup truck and the spotter's right hand was struck by the transformer, resulting in amputation of the ring fingertip.
An employee was wearing full PPE while emptying a 55-gallon drum of phosphorus pentoxide and fainted, collapsing and striking their head against the ground. The employee was hospitalized and it is likely that heat caused by wearing full body PPE contributed to fainting.
An employee was troubleshooting a plug in the super-absorbent polymer line. The employee opened an inspection port and their right hand was caught in a rotary valve, resulting in the amputation of four fingers between the knuckle and the first joint.
An employee was conducting a quality control measure by taking a chemical sample for lab analysis. When the employee was opening the sample point, it broke off and crude 2-Ethylhexyl thioglycolate (EHTG) shot out at 265 degrees, and it covered the employee's legs and right arm and splashed the right side of their face. The employee was hospitalized with first- and second-degree burns to their right thigh, lower right knee, inner left thigh, and upper left forearm.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.
An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.
On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.