Federal OSHA recorded a severe workplace injury
at UE Compression LLC, 9461 Willow Court, HENDERSON, COLORADO 80640
on — Fractures , affecting the Pelvis.
Final narrative
An employee was spotting a crane when the load (fabricated skid for packaged equipment) that was being picked up came loose and fell on the employee. The employee sustained a crush injury resulting in a fractured pelvis.
The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.
An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
An employee was setting up dies on a die casting machine. The machine's ram unexpectedly returned from the down position and caught the tip of the employee's right thumb against a pinch point in the shot sleeve. The employee suffered an open fracture/amputation to the thumb tip. The machine was not locked out at the time.
Employee 1 was cleaning a paint gun using paint thinner when employee 2 started a lighter nearby and the cup of paint thinner ignited. Employee 2 dropped the cup and the ignited paint thinner spilled, causing burns on employee 2's arms, legs, hands, and face.
An employee was servicing a reciprocating air compressor when their left middle finger was caught in a belt motor pulley sheave while manually moving the belt. Approximately 1/4 inch of the employee's left middle fingertip was amputated.
An employee was checking the function of newly installed actuators when they were struck by a pressurized release pipe. The employee suffered fractures to the orbital socket and shoulder, requiring hospitalization.
An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.
A concrete batch plant operator was assisting with clearing spoil piles using a skid steer. The skid steer backed into a stationary screen plant. The employee's left little finger was crushed between the controls of the skid steer and the screen plant, resulting in a fracture and laceration. The employee's finger was surgically amputated.
An employee was standing on an extension ladder, using a torquing tool to remove bolts that secured blades to a rotor. When the torquing tool activated, its reaction arm came around and pinched the employee's right middle finger against a lifting eye. His fingertip was amputated.