Struck by running powered equipment during maintenance, cleaning, testing · Amputations involving bone loss
At a glance
Federal OSHA recorded a severe workplace injury
at HYDAC TECHNLOGY CORPORATION, HYDRAULIC DIVISION, 445 WINDY POINT DR, GLENDALE HEIGHTS, ILLINOIS 60139
on — Amputations involving bone loss, affecting the Finger or thumb tip(s), nail(s).
Final narrative
An employee was working in the shipping/receiving area on a packing paper dispenser that was jammed. When the paper came free, the blade pulled the paper in and pulled the employee's hand in too, amputating about a quarter of the right middle fingernail and the top of the finger.
Amputation Finger or thumb tip(s), nail(s) Packaging, wrapping, bundling machinery
A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.
A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.
More severe injuries in this industry (NAICS 333995)
On June 27, 2025, at approximately 7:00 PM, an employee was operating a cell that presses rings on a cylinder and welds the rings on. The cylinder was moving between the welding station and the press station when it fell off the holder. The employee went to place the cylinder back on the holder when the cell cycled and the compression holder crushed their right hand. The employee's middle, ring, and little fingers were crushed.
An employee was working on a hydraulic cylinder at his work table. While he was removing a bleeder plug to reduce the pressure, the 3/8-inch steel plug was pushed out by oil pressure. The plug impacted his wrist, causing an abrasion where hydraulic oil went into his arm. The employee was hospitalized.
An employee was pulling a steel cart backward when his left ring finger was crushed between the cart and another steel cart, resulting in amputation of the fingertip.
An employee was using a hydraulic press to repair a hydraulic tool that was stuck in the open position. Upon adding downward pressure from the hydraulic press, the tool's hydraulic quick coupler broke and released the ball bearing inside the coupler. The ball bearing struck the employee in the abdomen, resulting in lacerations and abrasions. The ball bearing also penetrated the employee's abdomen.
An employee was operating a manual tube lathe when a piece of metal stringer (twine rope) caught his left forearm, resulting in a laceration. The employee was hospitalized and had surgery.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was driving a boom lift (in the lowered position) in an exterior dock area. The lift s left wheels rolled onto base plates that covered a 3-foot-deep sump pit. The base plates failed, and one side of the lift dropped. The employee's left leg was caught under the lift basket, and he suffered a fracture to the lower leg including the ankle.