ERIE, PA —
OSHA Inspection: ESSENTRA PLASTICS, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of ESSENTRA PLASTICS, LLC in 2614 MCCLELLAND AVENUE, ERIE, PA 16510 (NAICS 326199). OSHA activity number 344046321.
Where did this inspection happen?
- Establishment
- ESSENTRA PLASTICS, LLC
- Site address
- 2614 MCCLELLAND AVENUE
- City
- ERIE
- State
- PA
- ZIP
- 16510
- Mailing
- 2614 MCCLELLAND AVENUE, ERIE, PA 16510
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 39
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.95 G06
- Issued
- Abate by
- Penalty
- Initial $4347.00 · Current $3043.00 Reduced
81108111
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : a) Essentra Plastics, LLC DBA Essentra Components, 2614 McClelland Avenue, Erie, PA - The company did not provide annual audiometric testing for employees exposed to noise above the action level. On or about June 13, 2019, the following noise exposures were measured: 1. A machine operator was exposed to a mixed noise level of 95.4 dBA or an equivalent dose of 212.5%, as an 8-hour TWA, while operating dip mold machine #3. This level was based on 445 minutes of sampling; zero exposure was considered for the unsampled time. Audiometric testing was last provided May 2018; and 2. A machine operator was exposed to a mixed noise level of 88.6 dBA or an equivalent dose of 82.78%, as an 8-hour TWA, while operating dip mold machine #4. This level was based on 471 minutes of sampling; zero exposure was considered for the unsampled time. Audiometric testing was last provided April 2018.
Recent events (2)
- — I (S) $3042.9
- — Z (S) $4347
1910.95 G07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
81108111
General-duty citation text
29 CFR 1910.95(g)(7)(i): Each employee's annual audiogram was not compared to that employee's baseline audiogram to determine if the audiogram is valid and if a standard threshold shift as defined in 29 CFR 1910.95(g)(10) has occurred: a) Essentra Plastics, LLC DBA Essentra Components, 2614 McClelland Avenue, Erie, PA - The company did not ensure employee annual audiograms were compared to that employee's baseline audiogram to determine if the audiogram was valid and if a standard threshold shift had occurred: On or about June 13, 2019, the following noise exposures were measured: 1. A machine operator was exposed to a mixed noise level of 95.4 dBA or an equivalent dose of 212.5%, as an 8-hour TWA, while operating dip mold machine #3. This level was based on 445 minutes of sampling; zero exposure was considered for the unsampled time; and 2. A machine operator was exposed to a mixed noise level of 88.6 dBA or an equivalent dose of 82.78%, as an 8-hour TWA, while operating dip mold machine #4. This level was based on 471 minutes of sampling; zero exposure was considered for the unsampled time. Audiometric testing was last provided April 2018. Baseline audiograms were not provided to the audiometric testing company for comparison to 2018 audiometric tests.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 K02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
81108111
General-duty citation text
29 CFR 1910.95(k)(2): The training program was not repeated annually for each employee included in the hearing conservation program: a) Essentra Plastics, LLC DBA Essentra Components, 2614 McClelland Avenue, Erie, PA - The company did not provide annual hearing conservation training for employees exposed to noise above the action level. On or about June 13, 2019, the following noise exposures were measured: 1. A machine operator was exposed to a mixed noise level of 95.4 dBA or an equivalent dose of 212.5%, as an 8-hour TWA, while operating dip mold machine #3. This level was based on 445 minutes of sampling; zero exposure was considered for the unsampled time. Hearing conservation training was last provided May 2018; and 2. A machine operator was exposed to a mixed noise level of 88.6 dBA or an equivalent dose of 82.78%, as an 8-hour TWA, while operating dip mold machine #4. This level was based on 471 minutes of sampling; zero exposure was considered for the unsampled time. Hearing conservation training was last provided April 2018.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 L01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
81108111
General-duty citation text
29 CFR 1910.95(l)(1): The employer did not make available to affected employees or their representatives copies of 29 CFR 1910.95 and did not post a copy in the workplace: a) Essentra Plastics, LLC DBA Essentra Components, 2614 McClelland Avenue, Erie, PA - A copy of 29 CFR 1910.95 was not made available to employees exposed to noise above the action level. On or about June 13, 2019, the following noise exposures were measured: 1. A machine operator was exposed to a mixed noise level of 95.4 dBA or an equivalent dose of 212.5%, as an 8-hour TWA, while operating dip mold machine 3. This level was based on 445 minutes of sampling; zero exposure was considered for the unsampled time; and 2. A machine operator was exposed to a mixed noise level of 88.6 dBA or an equivalent dose of 82.78%, as an 8-hour TWA, while operating dip mold machine 4. This level was based on 471 minutes of sampling; zero exposure was considered for the unsampled time.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at ESSENTRA PLASTICS, LLC
ERIE, PA—2021-10-22 00:00:00
ESSENTRA PLASTICS, LLC
ERIE, PA—2021-10-22 00:00:00
ESSENTRA PLASTICS, LLC
ERIE, PA—2019-05-22 00:00:00
ESSENTRA PLASTICS, LLC
ERIE, PA—2017-01-12 00:00:00
ESSENTRA PLASTICS, LLC
ERIE, PA—2016-08-24 00:00:00
ESSENTRA PLASTICS, LLC
View ESSENTRA PLASTICS, LLC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344046321.