An employee cut two right-hand middle fingers while using a 280-inch band saw. Guards were in place at the time of the incident.
Two employees were struck by the rotary table of a drilling rig while installing caisson. Employee 1 suffered multiple fractures, internal injuries, and head trauma. Employee 2 suffered multiple fractures, internal injuries, spinal injury, and head trauma.
Employees were felling hazard trees. The injured employee was conducting 'bucking' operations to saw a tree from the road when the tree kicked-back, pinning him against the ground and fracturing his left femur. The employee was hospitalized and required surgery.
An employee was chaining a vehicle when he had to change tools and the compressor. As the compressor was being charged, the employee stepped near the vehicle to make sure the compressor was attached. Then, he instructed a co-worker to lower the compressor. His right hand was on the compressor and under the chain, causing his ring finger to be crushed.
More severe injuries in this industry (NAICS 331524)
An employee was grinding raw couplings on a belt sander to shave off excess material left by the manufacturing process. The employee's right hand slipped while he was pressing a part to the sander, causing his right thumb to come into contact with the sanding belt. The thumb was lacerated and broken, and the employee was hospitalized, requiring surgery.
An employee was buffing a corner casting when the rotating belt contacted her right hand, resulting in an amputation of the first segment of her right thumb.
An employee was assembling boilers, which involved stacking the flat sections of boilers on top of one another and pushing them down a non-powered roller line. While the employee was pushing a stack onto the next set of rollers, the stack became crooked. The employee went to pull back the stack to straighten it when their finger was pinched by a roller. The employee sustained a partial amputation to their left ring fingertip.
On June 25, 2025, at 7.30 a.m., an employee was using a remote-controlled crane to change a die in a 2,600-ton press. They were releasing crane cables from the die when one cable did not release, causing the die to lift and pin the employee between the press and the die. The employee suffered a closed non-displaced fracture of the pelvis.
An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.
An employee was standing on a multi-purpose ladder installing head flashing over a window. Their feet were approximately 6 feet off the ground and three rungs from the top. The employee lost their grip on the drill they were using and the ladder tipped over. The employee fell from the ladder to the ground, resulting in a fractured left wrist, bruised chest, and lacerations to their face and lip.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
An employee was loading a 4-inch wooden door into a pickup truck when he felt a pop in his right side behind his shoulder blade. He was hospitalized later that day and underwent surgery, having suffered a collapsed right lung.