Federal OSHA recorded a severe workplace injury
at Towercom Technologies LLC, Packer John Rd. MM7, BANKS, IDAHO 83602
on — Fractures, affecting the leg(s), unspecified.
Watch Towercom Technologies LLC — freeGet an email when a new federal OSHA severe-injury report for Towercom Technologies LLC is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was driving an excavator up a mountain road. The excavator hit a patch of ice, slid off the side of the road and rolled over. A tree stump came through the cab and pinned the operator's leg between the stump and the controls.
An employee was operating a sit-down type of material handling equipment (MHE). They were turning the MHE with the clamp attachment in the air when the MHE fell over onto its right side. The employee's right foot was caught under the battery cover of the MHE. The employee sustained a chemical burn from the battery and a fractured right ankle.
An employee was driving an unloaded forklift outside a building. During a left turn, the forklift drove off the paved area onto an unpaved surface, became unstable, and tipped over. The employee was pinned under the forklift and suffered two broken leg bones and a broken hip.
An employee was trimming tree branches from an aerial lift. As they were maneuvering the aerial bucket lift from inside, the truck drove over soft ground and tipped over. The bucket lift fell to the ground with the employee tied off inside, resulting in rib fractures.
More severe injuries in this industry (NAICS 237130)
An employee was terminating cables in a junction box. A loose ground wire came into contact with the bushing, causing a flash that burned the right side of the employee's face and his right hand.
An employee was using a bucket truck hoist to raise secondary aerial wiring. The wire made contact with the primary wire, causing an arc flash. The employee suffered burns to both hands and was hospitalized.
An employee was terminating conductors to buss bars inside the secondary compartment of a single-phase transformer. An arc flash occurred, causing burns to the soft tissue of the employee's face.
An employee was securing the claw of a grapple truck to the truck bed. His left little finger was caught between the tie down strap and the rub rail of the truck, resulting in partial amputation of the finger.
An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.
An employee was standing on a multi-purpose ladder installing head flashing over a window. Their feet were approximately 6 feet off the ground and three rungs from the top. The employee lost their grip on the drill they were using and the ladder tipped over. The employee fell from the ladder to the ground, resulting in a fractured left wrist, bruised chest, and lacerations to their face and lip.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
An employee was loading a 4-inch wooden door into a pickup truck when he felt a pop in his right side behind his shoulder blade. He was hospitalized later that day and underwent surgery, having suffered a collapsed right lung.