Caught in running equipment or machinery, n.e.c. · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Nemak Corporation, 4243 Gateway Drive, SHEBOYGAN, WISCONSIN 53081
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Final narrative
As an employee was verifying that the air pressure on a die-cast machine was at the correct level, the valve actuated and amputated the employee's third right-hand distal phalange.
An employee was dumping a tray of water when her right hand struck the side of a machine. She suffered a contusion that required surgery. The machine was unguarded at the time.
On November 30, 2016, an employee was working on the magna vc line and received a crushing injury when a finger was pinched between the slide and the part that was being repaired. On December 23, 2016, the right index finger was amputated.
An employee was working on a trim cell unit where engine blocks are trimmed out. As he was picking up the block, he was wearing a hot mill style glove. His pinky went into the chain belt and was caught between the backside of the chain belt and the guard. His left pinky finger was amputated.
Employees were assembling and testing a butterfly valve unit and actuator combo. When the unit was function tested with air, the valve gate closed on an employee's left thumb resulting in a fracture and laceration.
An employee was doing a daily inspection of the sifter screen on a mixer when the mixer line activated. The armature for the screen struck the employee's right wrist. Their wrist was cut and their hand was fractured.
An employee was doing a dry run during the setup of an ice cream machine. The machine indexed and the filler head amputated the employee's left middle finger above the last knuckle.
An employee was on a 3-foot ladder guiding cable onto a spool during installation on an overhead door. As the control box was jogged, the employee's hand was caught between the cable and spool, resulting in a wrist and hand fracture.
More severe injuries in this industry (NAICS 331523)
An employee was adjusting the oscillator pressure injector on a die-cast machine when his right thumb contacted the adjustment handle. The machine oscillated and closed on his right thumb. The tip of the thumb was pinched and amputated between the die and the handle.
An employee in the melt department was getting ready to put a recirculation pump into the pump housing area. He first put the pump in a cabinet to warm it up to avoid thermal shock. It shifted and the cold refractory contacted the hot metal. Molten metal contacted the employee, resulting in third-degree burns between their knee(s) and ankle(s). The employee was wearing some personal protective equipment (PPE) at the time but this was breached by the molten metal.
On May 15, 2025, an employee was assisting with troubleshooting an issue with a die in a die casting machine. While unjamming the machine, the employee's finger was caught between a section of the die and a wooden spacer. The employee's left middle fingertip was amputated.
An employee was checking the die casting machine when the cavity access door closed behind him and the employee sustained eight fractured ribs. The employee was hospitalized.
An employee was using a vertical band saw to cut a piece of square metal tubing when their left hand contacted the saw blade and their middle finger was amputated.
The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.
An employee was using a vertical band saw to cut a thick piece of rubber material. While being cut, the material shifted, causing the employee s right hand to contact the moving blade. The employee's thumb was amputated below the knuckle. The employee was hospitalized, undergoing surgery.
A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.
An employee was on a ladder, taking measurements for a new gutter installation. The ladder slipped out from under him and both he and the ladder fell to the ground. He was hospitalized with seven broken ribs and a broken clavicle.
An employee was unloading a truck for a delivery job. While moving boxes in the truck, the employee tripped over a pallet and fell out of the truck to the ground, resulting in four broken ribs.