105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Eastman Chemical Company, Texas Operations

Ignition of vapors, gases, or liquids · Heat (thermal) burns, unspecified

Federal OSHA recorded a severe workplace injury at Eastman Chemical Company, Texas Operations, 300 Kodak Blvd., LONGVIEW, TEXAS 75602 on — Heat (thermal) burns, unspecified, affecting the upper and lower limb(s).

An employee was making his rounds when he identified a level indication in the vessel that he was not sure was accurate. He then drained the sit glass and the material (mineral spirits polyethylene wax and ethaline gas) ignited a flash fire, burning his left palm, both forearms, and his left calf. He was hospitalized.

Hospitalized Upper and lower limb(s) Chemicals and chemical products, n.e.c.

Eastman Chemical Company, Texas Operations

An employee was preparing to climb an 8-foot scaffold ladder to install a 6-inch piping blind flange. As the employee climbed to the fourth rung of the ladder, he struck the top of his hardhat on an overhead pipe. The employee fell from the scaffold ladder approximately 4-5 feet before landing on his hip and striking his head on the ground. He sustained spine and neck injuries that required surgery.

View Eastman Chemical Company, Texas Operations's full OSHA safety record →

Sam Galloway Ford, Inc.

An employee was cleaning a cordless drill. As they applied brake fluid to the drill and pulled the trigger, the fluid ignited. The employee suffered burns to the face, hands, and arms.

Canfor Southern Pine, Inc.

An employee was welding on a rack when sparks ignited residual diesel on his pants. The employee sustained first-, second-, and third-degree burns.

Freedom Trailers, LLC

An employee was spraying glue to the floor of an enclosed cargo trailer. The fumes made contact with the heater causing a flash fire. The employee suffered burns to their face and right hand.

Flora-Bama Management, LLC

An employee was replacing a valve in the gas line to the fryer. The shutoff valve malfunctioned resulting in a gas leak that then ignited. The employee sustained burns requiring hospitalization.

JANUS INTERNATIONAL GROUP, LLC

An employee was using a torch when a hole in the oxygen line leaked gas that then ignited. The employee sustained burns to the left palm and wrist.

Chevron-Phillips Chemical Company, LP

An employee was climbing into the cab of a semi-tractor when he stepped on the battery cover and it shifted from under him, causing him to fall to the ground. The employee sustained a fractured left wrist.

Chemtrade Solutions LLC

An employee was clearing a product flow restriction when the rotating valve activated. They sustained amputations to their left middle and index fingers.

Mapei Corporation

A panel was being lifted when an attached roller (approximately 20 pounds) slipped and fell about 2 feet onto the hard hat of an employee working below. The roller also struck the employee's shoulder and back. The employee was hospitalized and suffered a contusion to the shoulder/back.

Chemtrade Solutions LLC

An employee drank water from a water cooler in the control room that was contaminated with sodium nitrite. The employee sustained methemoglobinemia and was hospitalized.

Kureha PGA LLC

An employee was collecting waste material and taking it to a waste container that was in close proximity to material that was emitting chemical fumes due to elevated temperatures. The employee inhaled the fumes and was admitted to the hospital due to the exposure.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.