Other fall to lower level, unspecified · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Baron Analytical Laboratories, LLC, 181 Research Drive, MILFORD, CONNECTICUT 06460
on — Fractures, affecting the head and trunk.
Final narrative
An employee fell from a ladder while accessing a mezzanine, suffering four cracked ribs and a fracture to the base of the head.
An employee was on an A-frame ladder retrieving materials from a shelf. He slipped and fell and his leg got caught in the ladder rungs, breaking his left tibia.
An employee was unloading materials from a flatbed trailer when they fell from the trailer and landed on the ground. The employee sustained a fractured left leg.
An employee was unloading appliances at a customer location for delivery. The employee was moving a water heater to be placed on the liftgate when he stepped backward and fell to the ground. The employee sustained rib and back injuries.
An employee was operating a horizontal belt sanding machine that rotates a metal sanding belt. The employee switched hands while the belt transitioned from left to right. When the machine's speed was adjusted, the employee s left hand was pulled into the machine and crushed. The employee was hospitalized and required surgery.
An X-ray machine had lost power and an employee went to replace the power supply. While replacing a cable on the power supply assembly, the employee's right hand contacted the grounding terminals coming out of the back of the power supply assembly and they received an electric shock. The employee was hospitalized.
On March 19, 2025, an employee was retrieving a medical specimen from the back of a vehicle. When he turned to enter the building, he either tripped over something or lost his footing and fell due to an incline in the pavement. The employee was hospitalized with a head abrasion and injuries to his right shoulder and right hip.
Employees were pulling a chemical sample from a device (sample port). The sample wouldn't come out because there were two samples in the port. The employees then turned off and deenergized the machine to 0 pounds per square inch. They unscrewed the top of the machine to retrieve the stuck samples when a small amount of pressure caused liquid to squirt out and onto one of the employee's face shields as the lid was removed. The employee was hospitalized due to chemical exposure.
An employee was walking around a boiler recovery tank when they stepped into an uncovered U-drain filled with hot water. The employee sustained second-degree burns to their right leg and the top of their foot.
An employee was checking on a machine outside of the building and removed a cover to clean out a blocked area. His hand was caught by a rotary valve in a dust collection machine. The employee's fingertip was amputated.
An employee was working to clean a glue roller with a scraper tool. The tool and the employee's left thumb were pinched between two rollers, resulting in a partial amputation.
An employee was re-arranging boxes of pipe insulation on a pallet. One of the boxes fell from the pallet and knocked over an upright empty cylinder. The cylinder fell and crushed the tip of the employee's right toe. The employee's toe required surgical amputation.
An employee was securing the claw of a grapple truck to the truck bed. His left little finger was caught between the tie down strap and the rub rail of the truck, resulting in partial amputation of the finger.
An employee was cutting extruded aluminum framing material using a horizontal band saw. She went to grab a rag in the machine when the rag contacted the blade and pulled her hand in toward the blade, resulting in a partial amputation of the right index finger.