105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Pactiv LLC

Caught in running equipment or machinery during maintenance, cleaning · Amputations

Federal OSHA recorded a severe workplace injury at Pactiv LLC, 2120 Westbelt Drive, COLUMBUS, OHIO 43228 on — Amputations, affecting the finger(s), fingernail(s), unspecified.

On February 19, 2020, an employee was cleaning a roll on a printer press when the employee's hand was pulled into a running nip point on the press. The employee suffered a partial amputation of the right thumb and right middle finger as well as damage to the right pinky finger.

Amputation Finger(s), fingernail(s), unspecified Presses-printing

Pactiv LLC

An employee jumped up on the concrete floor to retrieve an empty 5-gallon bucket from on top of a storage cabinet. When he landed, his right femur fractured.

Pactiv, LLC

On January 6, 2025, at approximately 11:56 PM, an employee was clearing products from the packing table of a trim press when their left middle finger came in contact with the die. The employee sustained amputation of their left middle finger pad.

PACTIV LLC

An employee was removing plastic shards from a machine using a compressed air hose. She stepped on the guardrail to gain better access to the accumulated plastic and her hair was caught in the rotating canopy drive shaft. The employee suffered hair loss and scalp damage. The machine was not guarded at the time.

PACTIV LLC

An employee's face struck the handle on a machine resulting in chipped teeth and a laceration inside the mouth.

PACTIV LLC

An employee was traveling forward in a forklift when it struck a support beam. The employee sustained a fractured femur.

View Pactiv LLC's full OSHA safety record →

DGS Import, LLC

An employee was changing a saw blade when the saw machine activated. The employee's left ring and little fingers were amputated.

Millennium Mat Company

An employee was clearing a jam from the label cutting machine when their left middle finger was partially amputated.

Bauer Foundation Corp.

Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.

Guggisberg Cheese, Inc.

An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.

Alsco Inc.

An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.

Sealed Air Corp.

At about 11:00 a.m. on August 17, 2025, a Sealer Air Corp. employee suffered a broken right tibia while stepping down from a conveyor to the floor 19 inches below.

PAC Worldwide Corporation

A maintenance employee was repairing the labeler on the line when it fell on their head, resulting in a broken jaw.

Hilex Poly, A Novolex Brand

An employee was troubleshooting around the secondary draw rollers of a bag machine when their left index, middle, and ring fingers contacted the rollers. The employee sustained a partial fingertip amputation to one of the fingers. The machine was not guarded at the time.

Pitt Plastics, Inc.

An employee was clearing a jam from the rewinder when their hand was pulled into a rotating part of the machine, fracturing one finger and dislocating another.

Berry Global

An employee was stepping down from a two-step ladder when the ladder slipped out from underneath them. The employee fell and landed on a sidekick trailer jack, resulting in four fractured ribs, including two ribs with multiple breaks, and a pulmonary contusion.

United States Postal Service

An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.

Foundation Steel, LLC

An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.

GXO Logistics

On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.