Contact with objects and equipment, unspecified · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at SAC Wireless, LLC, 750 Davistown Rd, BLACKWOOD, NEW JERSEY 08012
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was installing equipment on a cell tower. As the employee was untangling cables, a mounting bracket crushed the employee's left middle finger. The fingertip was medically amputated.
A 3-inch rigid steel pipe was being set under a raised concrete slab. The pipe struck an employee in the upper torso and head. The employee suffered facial fractures and a skull fracture and was hospitalized.
An employee was operating a capstan hoist when two fingers on his right hand were caught between the rope and the drum of the hoist resulting in amputation of the distal phalanges.
Two employees were struck by the rotary table of a drilling rig while installing caisson. Employee 1 suffered multiple fractures, internal injuries, and head trauma. Employee 2 suffered multiple fractures, internal injuries, spinal injury, and head trauma.
Employees were felling hazard trees. The injured employee was conducting 'bucking' operations to saw a tree from the road when the tree kicked-back, pinning him against the ground and fracturing his left femur. The employee was hospitalized and required surgery.
An employee was chaining a vehicle when he had to change tools and the compressor. As the compressor was being charged, the employee stepped near the vehicle to make sure the compressor was attached. Then, he instructed a co-worker to lower the compressor. His right hand was on the compressor and under the chain, causing his ring finger to be crushed.
More severe injuries in this industry (NAICS 237130)
An employee was terminating cables in a junction box. A loose ground wire came into contact with the bushing, causing a flash that burned the right side of the employee's face and his right hand.
An employee was using a bucket truck hoist to raise secondary aerial wiring. The wire made contact with the primary wire, causing an arc flash. The employee suffered burns to both hands and was hospitalized.
An employee was terminating conductors to buss bars inside the secondary compartment of a single-phase transformer. An arc flash occurred, causing burns to the soft tissue of the employee's face.
An employee was securing the claw of a grapple truck to the truck bed. His left little finger was caught between the tie down strap and the rub rail of the truck, resulting in partial amputation of the finger.
An employee was installing fence posts when they stepped into a recently dug hole that was not visible due to rainfall. The employee's leg was fractured.
An employee assisted in cleaning material from a conveyor pit. After the pit was cleaned, the employee proceeded to replace metal safety plates to ensure other employees did not fall into the pit. While replacing one of the last plates, the employee mis-stepped and fell approximately 5 feet into the pit. The employee was hospitalized with back/side bruising, elbow bruising, bone bruises, and/or fractured ribs.
An employee was walking on the sidewalk. When they stepped off the curb, they fell to the ground, resulting in fractures to their tibia, fibula, and a metatarsal.