Delphinus Engineering, Inc.

Direct exposure to electricity, unspecified · Electrocutions, electric shocks

Federal OSHA recorded a severe workplace injury at Delphinus Engineering, Inc., USS Roosevelt, Puget Sound Naval Shipyard, BREMERTON, WASHINGTON 98310 on — Electrocutions, electric shocks, affecting the bODY SYSTEMS.

An employee sustained an electrical shock while performing stick welding, resulting in an arrhythmia.

Hospitalized BODY SYSTEMS Welding and heating handtools-powered, n.e.c.

Delphinus Engineering Inc

On July 17, 2018, an employee was working in an elevator platform when one of the hoist sheaves suddenly rotated and hit him in the head. It then returned to its original position, knocking off his hardhat and lacerating his scalp.

Delphinus Engineering Inc

An employee was walking on the gangway from a ship to a pier when he tripped and fell, bruising and potentially cracking his ribs. He was hospitalized.

View Delphinus Engineering, Inc.'s full OSHA safety record →

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

Ingalls Shipbuilding

An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.

Electric Boat Corporation

An employee was struck by a plasma cutter and suffered a broken left tibia and fibula. The employee was hospitalized.

Ingalls Shipbuilding, Inc

An employee was preparing to bend a flat bar in a brake press. When the machine was jogged, the stock rotated up and crushed his left middle fingertip against the outer frame of the die. The fingertip was amputated.

All Star Metals, LLC

An employee was cutting metal with a torch. A piece of metal struck the employee's left foot, causing multiple fractures to metatarsal(s). The employee was hospitalized.

Ingalls Shipbuilding, Inc

An employee was descending a ladder carrying a bag of trash. He fell, landed on the ground about 10 feet below, and suffered fractures to his right hip and pelvis.

Industrial Resources, Inc.

An employee was drilling a hole into the sealed hold of a vessel so a marine chemist could test its atmosphere. Upon drilling the hole, a gas that was under pressure was released and caught fire at the drill motor, where the employee was holding it. The employee was burned.

Navy NAVFAC-NW

An employee was performing restoration activities outside a 45-gallon condensation tank of a boiler system. As they were performing post-maintenance activities after repairing one of the two discharge pumps, one of the discharge valves would not open. The employee closed the intake pump to cool off the system and open the discharge valve. Two employees opened the inlet valve to return the tank to service. After they cracked open the inlet valve, a side wall of the tank blew out, causing the injured employee to suffer steam burns to half their body.

Yakama Forest Products

An employee was testing and troubleshooting the gang cylinder valve located in the gang area of the sawmill. The employee's fingertip was amputated by the gang cylinder valve.

SSA TERMINALS LLC

An employee was unlocking containers on deck. The employee was de-lashing while standing on the edge of the lid. The lashing bar he was holding came off the cone, causing him to turn 90 degrees and strike a railing behind him. The employee sustained four fractured ribs.

JONES STEVEDORING COMPANY

An employee parked a side-by-side on the fixed internal ramp aboard a cargo ship. They exited the side-by-side and went to inspect the cargo below. The side-by-side rolled toward the employee and struck them as they were walking toward the edge of the ramp. The employee was knocked off the ramp and landed on the lower deck approximately 8 feet below. The employee was hospitalized with a fractured shoulder.