105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Spirit Aerosystems, Inc.

Struck by running powered equipment during maintenance, cleaning, testing · Amputations involving bone loss

Federal OSHA recorded a severe workplace injury at Spirit Aerosystems, Inc., 3801 S Oliver, WICHITA, KANSAS 67210 on — Amputations involving bone loss, affecting the Other finger(s) n.e.c..

An employee was working inside the access panel of a sliding door when the door began to shut. The employee's left middle finger was pulled into the chain and sprocket, resulting in amputation to the middle knuckle.

Amputation Other finger(s) n.e.c. Doors swinging and sliding

Spirit Aerosystems, Inc

A metal tooling base was being moved by a forklift when the load shifted. An employee who was assisting went to stabilize the load and prevent it from sliding off the forks. The C-channel of the base crushed the employee's left hand against the concrete ground, resulting in the amputation of their third and fourth fingers.

Spirit Aerosystems Inc.

An employee was working on a tool platform (47.5" tall) and was transitioning around to the other side when they lost balance and fell to the concrete floor. The employee was hospitalized with fractures to seven ribs and their elbow.

SPIRIT AEROSYSTEMS, INC.

An employee was installing a rail on a machine. The roller pack was locked up, causing the chuck to not move. While manually removing the chuck, the rails were damaged. As a result, both the roller pack and the rail needed to be replaced. A fixed magnet from above the rail pulled the rail up and rolled it, pinching the employee's thumb between the rail and the magnet when he tried to install the new rail back to the position. The right thumb tip was amputated.

Spirit Aerosystems, Inc.

An employee was walking in the shop area, tripped on a work platform, and fell to the floor. The employee was hospitalized for a fractured femur.

Spirit Aerosystems, Inc.

An employee entered a freight elevator. The inside cage door came down and struck the top of the employee's head causing a contusion.

View Spirit Aerosystems, Inc.'s full OSHA safety record →

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

CFL USA, LLC

A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

Lockheed Martin Aeronautics Company

An employee was walking from one building to another when he slipped on wet concrete and fell. The employee was hospitalized with a fracture and dislocation of the right patella.

Ralmark Company

An employee was operating a mechanical press and amputated their left index fingertip. The press was not locked out/tagged out.

Woodward MPC, Inc.

An employee tripped over wire moldings and fell, sustaining a fractured left leg.

SPIRIT AEROSYSTEMS, INC.

An employee was installing a rail on a machine. The roller pack was locked up, causing the chuck to not move. While manually removing the chuck, the rails were damaged. As a result, both the roller pack and the rail needed to be replaced. A fixed magnet from above the rail pulled the rail up and rolled it, pinching the employee's thumb between the rail and the magnet when he tried to install the new rail back to the position. The right thumb tip was amputated.

Radius Aerospace Inc.

An employee was aligning wedges to plate bolt holes on a press when the plate moved while his right index finger was in a hole. The employee sustained a partial amputation of the finger.

Omya Inc.

An employee was working to remove a product blockage from a piece of equipment. The employee was struck by a metal bar near the deck of the pin mixer equipment and sustained blunt force trauma to the torso.

John Deere Coffeyville Works

An employee was moving a rack onto a lower conveyor in the south heat treat area when their finger got caught between the part tray and the rollers, resulting in a fingertip fracture and amputation.

Haven Steel Products Inc

An employee was climbing a ladder to get on top of the breakroom. The ladder slipped, causing him to fall to the ground. The employee sustained fractures to his upper back, left foot, and ankle.

Vestas-American Wind Tech

Two employees were removing a circuit breaker. The injured employee was using wrenches in the removal process. One of the wrenches contacted an adjacent door, resulting in an arc flash. The employee suffered burns to their neck, face, and ear, as well as momentary vision loss due to the flash.

Alliance Ag and Grain LLC

An employee bent over to pick up a rubber mat from the ground. When he grabbed the corner of the mat, a rattlesnake hidden under it bit his left middle finger near the first knuckle. He was hospitalized.