Other fall to lower level less than 6 feet · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Spirit Aerosystems Inc., 3801 S Oliver St., WICHITA, KANSAS 67210
on — Fractures , affecting the Trunk and other upper extremities.
Final narrative
An employee was working on a tool platform (47.5" tall) and was transitioning around to the other side when they lost balance and fell to the concrete floor. The employee was hospitalized with fractures to seven ribs and their elbow.
Hospitalized Trunk and other upper extremities Self-supporting scaffolds or staging
A metal tooling base was being moved by a forklift when the load shifted. An employee who was assisting went to stabilize the load and prevent it from sliding off the forks. The C-channel of the base crushed the employee's left hand against the concrete ground, resulting in the amputation of their third and fourth fingers.
An employee was working inside the access panel of a sliding door when the door began to shut. The employee's left middle finger was pulled into the chain and sprocket, resulting in amputation to the middle knuckle.
An employee was installing a rail on a machine. The roller pack was locked up, causing the chuck to not move. While manually removing the chuck, the rails were damaged. As a result, both the roller pack and the rail needed to be replaced. A fixed magnet from above the rail pulled the rail up and rolled it, pinching the employee's thumb between the rail and the magnet when he tried to install the new rail back to the position. The right thumb tip was amputated.
An employee fell while exiting a trailer. The employee landed on their left side on the pavement, suffering multiple broken ribs on the left side. The employee was hospitalized.
A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.
Two employees were removing a service lift platform from the back of a radar system. While handling the service lift platform, employee 2 was standing on the back of the radar and lost their footing, causing the service lift platform to shift and fall. The injured employee then fell from the top of the platform electronic subsystem (PES) to the floor, approximately 56 inches. The injured employee fractured his left elbow and left hip.
An employee fell from a loading dock to the ground 2-3 feet below. She suffered a compound fracture of the left hip and was hospitalized, requiring surgery.
An employee assisted in cleaning material from a conveyor pit. After the pit was cleaned, the employee proceeded to replace metal safety plates to ensure other employees did not fall into the pit. While replacing one of the last plates, the employee mis-stepped and fell approximately 5 feet into the pit. The employee was hospitalized with back/side bruising, elbow bruising, bone bruises, and/or fractured ribs.
More severe injuries in this industry (NAICS 336411)
A pressurized aircraft nose landing gear strut assembly was being disassembled. The gland nut dislodged under pressure and made contact with an employee's left hand, breaking it.
A metal tooling base was being moved by a forklift when the load shifted. An employee who was assisting went to stabilize the load and prevent it from sliding off the forks. The C-channel of the base crushed the employee's left hand against the concrete ground, resulting in the amputation of their third and fourth fingers.
On August 19, 2025, at 6:30 a.m., an employee sat in the rear bench seat of a golf cart ahead of being driven to a parking lot. When the golf cart began to move, he fell off the cart and onto the ground, resulting in a fractured right hip.
An employee was preparing the wing of an aircraft for stripping work and was standing on a four-foot step stand. As the employee was walking on the top platform of the stand, they stepped off the end of the stand and fell to the ground. The employee sustained fractures to their left elbow and left hip.
An employee was working to remove a product blockage from a piece of equipment. The employee was struck by a metal bar near the deck of the pin mixer equipment and sustained blunt force trauma to the torso.
An employee was moving a rack onto a lower conveyor in the south heat treat area when their finger got caught between the part tray and the rollers, resulting in a fingertip fracture and amputation.
An employee was climbing a ladder to get on top of the breakroom. The ladder slipped, causing him to fall to the ground. The employee sustained fractures to his upper back, left foot, and ankle.
Two employees were removing a circuit breaker. The injured employee was using wrenches in the removal process. One of the wrenches contacted an adjacent door, resulting in an arc flash. The employee suffered burns to their neck, face, and ear, as well as momentary vision loss due to the flash.
An employee bent over to pick up a rubber mat from the ground. When he grabbed the corner of the mat, a rattlesnake hidden under it bit his left middle finger near the first knuckle. He was hospitalized.