Federal OSHA recorded a severe workplace injury
at Joseph T Ryerson & Son, Inc, 555 N. Yearling Rd., COLUMBUS, OHIO 43213
on — Fractures , affecting the Ankle(s) and leg(s) unspecified.
Final narrative
An employee was using an overhead crane with a sheet lifter to move two stacks of carbon plates. They were standing in-between the two stacks as the sheet lifter lowered onto one of the stacks. The bundled material slipped out and the employee's right ankle was pinned against the other stack, resulting in a fractured leg and ankle that required hospitalization.
Hospitalized Ankle(s) and leg(s) unspecified Bundles, bales
More severe injuries at Joseph T Ryerson & Son, Inc
An employee was moving 4-inch pieces of solid round material, cradled in a sling. The employee's right middle finger was pinched between two pieces of the material and partially amputated.
On June 29, 2021, an employee was unloading materials from a flat bed truck using an overhead crane and a nylon sling. While positioning the nylon sling to hoist a stack of 6"x12' aluminum round bars that was on top of 5"x12' rectangular flat bars, the round bars shifted, rolled back, and pinned the employee's left middle finger between a round bar and a flat bar, resulting in a fingertip amputation.
A maintenance employee was making adjustments to the measurements on a tube laser. The employee was inside the inter-lock doors when the machine started up. The employee was struck in the torso by the machine arm and suffered ruptured intestines and internal bleeding.
The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.
An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
A load of steel angles was being lowered when the lifting chain hit the load, causing it to slide toward an employee. An angle slid and pinched the employee, catching both of their legs between the beams and an angle. The employee suffered two fractured legs.
An employee was on the deck of a trailer helping a customer unload tubes. The employee was working to place a cargo strap on the remaining tubes using a winch bar when it slipped off the tubing, causing him to lose his balance and fall headfirst onto the asphalt lot below. The employee suffered a contusion on his forehead, resulting in hospitalization.
An employee and a customer were unloading two rectangular tubes. The tubes were wrapped together. The plastic wrap was cut so that one tube could be picked up. As the employee was lifting the top tube, the other tube (still connected to the top tube) came down onto his hand and broke two of his fingers. He was hospitalized.
An employee was assisting as a forklift got pipe from a pipe rack. The employee was on one of the forklift's forks as it was raised to the top of the rack, a height of about 15 feet. He fell to the ground and suffered a dislocated and fractured right elbow.
On September 23, 2025, at approximately 7:43 p.m., an employee was using a knife to cut poly banding from a metal coil. The knife slipped, causing a laceration to the inside of their left arm at the elbow joint. The employee was hospitalized and required surgery to repair a damaged vein.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.