PYOTE, TX —
OSHA Inspection: RIG POWER INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RIG POWER INC. in RIG #106, UNIVERSITY 17-17, WELL #106, PYOTE, TX 79777 (NAICS 238910). OSHA activity number 339606154.
Where did this inspection happen?
- Establishment
- RIG POWER INC.
- Site address
- RIG #106, UNIVERSITY 17-17, WELL #106
- City
- PYOTE
- State
- TX
- ZIP
- 79777
- Mailing
- 7600 W. COUNTY RD. 116, MIDLAND, TX 79706
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $2380.00
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about February 27, 2014, Capstar Rig #106, the 70KVA Diesel AC Power Generator #3143 was not grounded properly, the ground electrode rod, approximately 34-inches in length, was inserted approximately 6-inches into the earth. Employees were exposed to shock hazards.
Recent events (1)
- — Z (S) $2380
1910.305 G02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints and/or terminal screws: On or about February 27, 2014, Capstar Rig #106, the 240V black cable attached to the back of the Mud Logger Trailer #5115 had its strain relief broken which exposed the inner conductors to possible damage. Employees were exposed to shock hazards.
Recent events (1)
- — Z (O) $0
More inspections at RIG POWER INC.
EL PASO, TX—2015-02-24 00:00:00
RIG POWER INC.
PECOS, TX—2014-08-06 00:00:00
RIG POWER, INC.
MIDLAND, TX—2014-07-31 00:00:00
RIG POWER INC.
MIDLAND, TX—2014-07-30 00:00:00
RIG POWER INC.
PECOS, TX—2013-01-10 00:00:00
RIG POWER, INC.
View RIG POWER INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
SIOUX FALLS, SD—2026-07-10
SOUKUP CONSTRUCTION, INC.
TUCSON, AZ—2026-07-10
CPX2026XJL680X0074 - JANC EXCAVATING AND CONSTRUCTION, LLC
BAKERSFIELD, CA—2026-07-10
BENCHMARK PIPELINE INC.
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
AMERICAN CANYON, CA—2026-07-10
ENVIRONCARE INTERNATIONAL
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339606154.