Final narrative
A boiler plug was leaking and the new plug would not seal due to galling on the threads. Employees tried to grind the threads straight. A boiler gate valve was closed, so the employees used a spray of penetrating oil. Sparks from the grinding caused flames to release from the boiler. The pressure forced an employee backwards and led to burns on both of the employee's arms.
An employee was cleaning a cordless drill. As they applied brake fluid to the drill and pulled the trigger, the fluid ignited. The employee suffered burns to the face, hands, and arms.
An employee was spraying glue to the floor of an enclosed cargo trailer. The fumes made contact with the heater causing a flash fire. The employee suffered burns to their face and right hand.
An employee was replacing a valve in the gas line to the fryer. The shutoff valve malfunctioned resulting in a gas leak that then ignited. The employee sustained burns requiring hospitalization.
An employee was sorting sucker rods. His right hand was caught in the area where the rod hits up against the frame and his index fingertip was amputated just below the nail.
An employee was using a powered miter saw to cut 2x4's. The saw blade hit something inside a board (possibly a hidden nail) and jumped, causing a laceration to the employee's left forearm. The employee was hospitalized with soft tissue and tendon injuries that required surgery.
A crane had been used to set a steel plate on a steel frame. An employee was trying to remove a clamp from the plate when the plate fell and crushed the tip of his left little finger. The employee sustained a fingertip amputation.
An employee was operating a scissor lift, raised to a height of about 15 feet, to inspect an overhead crane rail. The crane itself was being moved. Its hook swung into the scissor lift s arms, causing the lift to tip over onto its side, which in turn caused the lift and the employee to fall to the floor. The employee suffered injuries including broken ribs, spinal fractures, scapula fractures, and internal injuries.
A technician was operating a crane hoist to lift/remove a cylinder head from the main engine (port). The load was lifted at an angle, causing the cylinder head to get stuck on the cylinder head studs. When it became free from the studs, the cylinder head swung. It struck the technician and caught them against the cabinet door. This resulted in an amputation of their left index fingertip at the distal knuckle.
An employee was readjusting a safety hook to remove hardware from gang forms when his feet slipped. He fell to the ground, resulting in a broken left arm and wrist.
An employee was on a step ladder in a store aisle, making room on shelving for merchandise. She fell from the step ladder to the floor, suffering two fractures in her left leg. She was hospitalized, requiring surgery.
An employee was closing the side cargo door to a company van. The tip of his finger got caught between the door and the door jamb, resulting in a partial amputation.